HVAC Sensors & Controllers
Filters
-
RS PRO Type NTC Temperature Sensor, -10°C → +60°C 813-806
Set screw probe fixed to brass and steel pocket for easy replacement • Temperature sensor for air conditioning • Thermistor and Pt100 type sensor in various packages ideal for use in most air conditioning control systems.
Sensor Type: Thermistor: Direct Thermistor (NTC) Temperature (10 kΩ, 25°C) type.1 products found
JPY: 3,470
USD: 21.75
-
RS PRO Type PT 100 Temperature Sensor, -30°C → +70°C 813-862
Set screw probe fixed to brass and steel pocket for easy replacement • Temperature sensor for air conditioning • Thermistor and Pt100 type sensor in various packages ideal for use in most air conditioning control systems.
Sensor Type: Thermistor: Direct Thermistor (NTC) Temperature (10 kΩ, 25°C) type.1 products found
JPY: 10,100
USD: 63.31
-
RS PRO Type PT 100 Temperature Sensor, -30°C → +70°C 813-878
Set screw probe fixed to brass and steel pocket for easy replacement • Temperature sensor for air conditioning • Thermistor and Pt100 type sensor in various packages ideal for use in most air conditioning control systems.
Sensor Type: Thermistor: Direct Thermistor (NTC) Temperature (10 kΩ, 25°C) type.1 products found
JPY: 7,380
USD: 46.26
-
RS PRO Type NTC Temperature Sensor, -10°C → +110°C 813-828
Set screw probe fixed to brass and steel pocket for easy replacement • Temperature sensor for air conditioning • Thermistor and Pt100 type sensor in various packages ideal for use in most air conditioning control systems. Sensor Type: Thermistor: Direct Thermistor (NTC) Temperature (10 kΩ, 25 °C) type. These are degradable components and must be replaced on a 2-3 year cycle. Pt100 sensor: A 2-wire sensor with a brass probe that provides linear response and positive temperature coefficient. Package Type: Space Air (; 813-806 813-806,; 376-1477 376-1477): White ventilator for internal use, temperature range -10 to +60 °C. Duct air (; 813-862 813-862): IP65 housing with 20 mm conduit entry, 210 x 19 mm diameter probe with fine mesh gauge for sensor protection, temperature range -10 to +60 °C. Outside Air (; 813-828 813-828,; 813-878 813-878): IP65 enclosure with small brass cap, 20 mm conduit entry, temperature range -10 to +60 °C. Immersion (; 813-834 813-834,; 813-884 813-884): Ideal for IP65 enclosure with 20 mm conduit entry, 130 x 6 mm diameter brass probe, brass pocket for temperature range -10 to +60 °C (sold separately). Pipe Clamp On (; 813-840 813-840,; 813-890 813-890): The detection element on the lug attached to the pipe through a stainless steel cable tie. IP65 terminal, 1 m cable, maximum temperature 110 °C
1 products found
JPY: 3,340
USD: 20.94
-
RS PRO Type NTC Temperature Sensor, -30°C → +70°C 813-834
Set screw probe fixed to brass and steel pocket for easy replacement • Temperature sensor for air conditioning • Thermistor and Pt100 type sensor in various packages ideal for use in most air conditioning control systems. Sensor Type: Thermistor: Direct Thermistor (NTC) Temperature (10 kΩ, 25 °C) type. These are degradable components and must be replaced on a 2-3 year cycle. Pt100 sensor: A 2-wire sensor with a brass probe that provides linear response and positive temperature coefficient. Package Type: Space Air (; 813-806 813-806,; 376-1477 376-1477): White ventilator for internal use, temperature range -10 to +60 °C. Duct air (; 813-862 813-862): IP65 housing with 20 mm conduit entry, 210 x 19 mm diameter probe with fine mesh gauge for sensor protection, temperature range -10 to +60 °C. Outside Air (; 813-828 813-828,; 813-878 813-878): IP65 enclosure with small brass cap, 20 mm conduit entry, temperature range -10 to +60 °C. Immersion (; 813-834 813-834,; 813-884 813-884): Ideal for IP65 enclosure with 20 mm conduit entry, 130 x 6 mm diameter brass probe, brass pocket for temperature range -10 to +60 °C (sold separately). Pipe Clamp On (; 813-840 813-840,; 813-890 813-890): The detection element on the lug attached to the pipe through a stainless steel cable tie. IP65 terminal, 1 m cable, maximum temperature 110 °C
1 products found
JPY: 8,330
USD: 52.22
-
RS PRO Type NTC Temperature Sensor, -30°C → +70°C 813-840
Set screw probe fixed to brass and steel pocket for easy replacement • Temperature sensor for air conditioning • Thermistor and Pt100 type sensor in various packages ideal for use in most air conditioning control systems. Sensor Type: Thermistor: Direct Thermistor (NTC) Temperature (10 kΩ, 25 °C) type. These are degradable components and must be replaced on a 2-3 year cycle. Pt100 sensor: A 2-wire sensor with a brass probe that provides linear response and positive temperature coefficient. Package Type: Space Air (; 813-806 813-806,; 376-1477 376-1477): White ventilator for internal use, temperature range -10 to +60 °C. Duct air (; 813-862 813-862): IP65 housing with 20 mm conduit entry, 210 x 19 mm diameter probe with fine mesh gauge for sensor protection, temperature range -10 to +60 °C. Outside Air (; 813-828 813-828,; 813-878 813-878): IP65 enclosure with small brass cap, 20 mm conduit entry, temperature range -10 to +60 °C. Immersion (; 813-834 813-834,; 813-884 813-884): Ideal for IP65 enclosure with 20 mm conduit entry, 130 x 6 mm diameter brass probe, brass pocket for temperature range -10 to +60 °C (sold separately). Pipe Clamp On (; 813-840 813-840,; 813-890 813-890): The detection element on the lug attached to the pipe through a stainless steel cable tie. IP65 terminal, 1 m cable, maximum temperature 110 °C
1 products found
JPY: 9,130
USD: 57.23
-
RS PRO Type PT 100 Temperature Sensor, -30°C → +70°C 813-884
Set screw probe fixed to brass and steel pocket for easy replacement • Temperature sensor for air conditioning • Thermistor and Pt100 type sensor in various packages ideal for use in most air conditioning control systems. Sensor Type: Thermistor: Direct Thermistor (NTC) Temperature (10 kΩ, 25 °C) type. These are degradable components and must be replaced on a 2-3 year cycle. Pt100 sensor: A 2-wire sensor with a brass probe that provides linear response and positive temperature coefficient. Package Type: Space Air (; 813-806 813-806,; 376-1477 376-1477): White ventilator for internal use, temperature range -10 to +60 °C. Duct air (; 813-862 813-862): IP65 housing with 20 mm conduit entry, 210 x 19 mm diameter probe with fine mesh gauge for sensor protection, temperature range -10 to +60 °C. Outside Air (; 813-828 813-828,; 813-878 813-878): IP65 enclosure with small brass cap, 20 mm conduit entry, temperature range -10 to +60 °C. Immersion (; 813-834 813-834,; 813-884 813-884): Ideal for IP65 enclosure with 20 mm conduit entry, 130 x 6 mm diameter brass probe, brass pocket for temperature range -10 to +60 °C (sold separately). Pipe Clamp On (; 813-840 813-840,; 813-890 813-890): The detection element on the lug attached to the pipe through a stainless steel cable tie. IP65 terminal, 1 m cable, maximum temperature 110 °C
1 products found
JPY: 9,420
USD: 59.05
-
RS PRO Type PT 100 Temperature Sensor, -30°C → +110°C 813-890
Set screw probe fixed to brass and steel pocket for easy replacement • Temperature sensor for air conditioning • Thermistor and Pt100 type sensor in various packages ideal for use in most air conditioning control systems. Sensor Type: Thermistor: Direct Thermistor (NTC) Temperature (10 kΩ, 25 °C) type. These are degradable components and must be replaced on a 2-3 year cycle. Pt100 sensor: A 2-wire sensor with a brass probe that provides linear response and positive temperature coefficient. Package Type: Space Air (; 813-806 813-806,; 376-1477 376-1477): White ventilator for internal use, temperature range -10 to +60 °C. Duct air (; 813-862 813-862): IP65 housing with 20 mm conduit entry, 210 x 19 mm diameter probe with fine mesh gauge for sensor protection, temperature range -10 to +60 °C. Outside Air (; 813-828 813-828,; 813-878 813-878): IP65 enclosure with small brass cap, 20 mm conduit entry, temperature range -10 to +60 °C. Immersion (; 813-834 813-834,; 813-884 813-884): Ideal for IP65 enclosure with 20 mm conduit entry, 130 x 6 mm diameter brass probe, brass pocket for temperature range -10 to +60 °C (sold separately). Pipe Clamp On (; 813-840 813-840,; 813-890 813-890): The detection element on the lug attached to the pipe through a stainless steel cable tie. IP65 terminal, 1 m cable, maximum temperature 110 °C
1 products found
JPY: 10,000
USD: 62.68
-
Temperature Sensor 0 → +50°C, RS PRO, Interior Room 312-2939
This range of RH sensors are not suitable for use in swimming pools and spa applications. Relative Humidity/Temperature Transmitters. High specification, relative humidity and temperature transmitters for use with building management systems. User configurable for 4-20mA or 0-10V outputs Microcontroller reduces measurement errors Two part terminals for ease of connection Polycarbonate housings Measurement range 10 to 90% RH. IP Rating. ; 312-2939 312-2939 - IP30 ; 312-2945 312-2945 - IP65 ; 312-2951 312-2951 - IP67
1 products found
JPY: 50,900
USD: 319.06
-
Temperature Sensor -20 → +50°C, RS PRO, Interior Room 312-2945
This range of RH sensors are not suitable for use in swimming pools and spa applications. Relative Humidity/Temperature Transmitters. High specification, relative humidity and temperature transmitters for use with building management systems. User configurable for 4-20mA or 0-10V outputs Microcontroller reduces measurement errors Two part terminals for ease of connection Polycarbonate housings Measurement range 10 to 90% RH. IP Rating. ; 312-2939 312-2939 - IP30 ; 312-2945 312-2945 - IP65 ; 312-2951 312-2951 - IP67
1 products found
JPY: 59,500
USD: 372.97
-
Temperature Sensor -20 → +50°C, RS PRO, Duct 312-2951
This range of RH sensors are not suitable for use in swimming pools and spa applications. Relative Humidity/Temperature Transmitters. High specification, relative humidity and temperature transmitters for use with building management systems. User configurable for 4-20mA or 0-10V outputs Microcontroller reduces measurement errors Two part terminals for ease of connection Polycarbonate housings Measurement range 10 to 90% RH. IP Rating. ; 312-2939 312-2939 - IP30 ; 312-2945 312-2945 - IP65 ; 312-2951 312-2951 - IP67
1 products found
JPY: 59,800
USD: 374.85
-
Eberle Thermostats, -20 → +35 °C FTRE 3121
FTR series temperature controllers. Thermostats to protect against freezing, in a plastic housing for use in damp environments. The FTR-E3121 is an electro-mechanical frost monitor, whereas the FTR 1207 is an electronic thermostat with indoor and outdoor settings. Settings on front panel Cable entry via PG13 cable gland.
1 products found
JPY: 35,300
USD: 221.28
-
RS PRO Thermostats 719-4168
Pipe Contact Thermostat
Cased unipolar thermostat with switch contacts and cable clamps. It is especially suitable for temperature measurement in pipes of heating equipment and other applications. The thermostat is clamped with a spring band that ensures good contact.1 products found
JPY: 5,760
USD: 36.11
-
Temperature Sensor -50 → +110°C, United Automation A86614, Interior Room, Thermistor A86614
Infresco 10K NTC Thermistor Sensor. Temperature range: -50 → +100°C (110°C max) 0.5 meter lead Fully encapsulated sensor, offering IP68 water protection Absolute integrity against moisture ingress Dielectric strength: 4kVac Suitable for refrigeration, air conditioning, solar and underfloor heating
1 products found
JPY: 2,460
USD: 15.42
-
40 → 90%RH NO Humidistat, 20 → 56 V dc 01012.0-20
Humidity Controller
1 products found
JPY: 65,300
USD: 409.33
-
Eberle Thermostats, 0 → +40 °C FTR 1207
FTR series temperature controllers. Thermostats to protect against freezing, in a plastic housing for use in damp environments. The FTR-E3121 is an electro-mechanical frost monitor, whereas the FTR 1207 is an electronic thermostat with indoor and outdoor settings. Settings on front panel Cable entry via PG13 cable gland.
1 products found
JPY: 30,600
USD: 191.81
-
Temperature Sensor -25 → +70°C, Eberle F891 000, Interior Room F 891 000
ITR 3 temperature controller. Universal temperature controller for distributor installation. Settings dial with range limitation. The control unit and detector must be ordered separately. For mounting onto DIN rail. Changeover output. Applications: floor heating systems and enclosed area heating.
1 products found
JPY: 10,300
USD: 64.57
-
[Discontinued]Grasslin Thermostats, 30 min, Maximum of 45 °C 04.10.0001.1
Programable Thermostat - FEELING Series. The Grässlin Feeling controller is a battery-powered programmable thermostat for 24 hour / 7 day control of space heating – suitable for a combination boiler, or for regulation of the space heating output from a system boiler. Allows setting of a temperature profile throughout the day, with individual day or day group programming. Temperatures can be set at half-hour increments in the range 5°C – 32°C. 3.0Vdc supply voltage (2 x AA alkaline batteries) Battery change reserve limit: 10 minutes Timing accuracy: typ ± 1 sec. / day @ 20° C Manual override Control range +5°C …. +32°C Display range 0°C …. +50°C Automatic daylight saving function Display parameters: Day, date, time, set temperature, Ambient temperature, mode, Programme graphic
1 products found
JPY: 19,300
USD: 120.98
