[Time Electronic]Calibrators
Filters
-
[Out of stock]Time Electronic 1017 Multi Function Calibrator 1017
internal rechargeable Ni-Cad battery pack. Time Electronics Model 1017 DC Multifunction Voltage/Current/Resistance Calibrator. Time Electronics 1017 is a high performance portable multifunction calibrator with voltage, current and resistance ranges. Its combination of precision and simple operation gives it versatility for workshop and field operations. The batteries are automatically recharged when the mains supply is connected. The compact, durable plastic case, with tilt stand/carry handle, takes up minimal bench space and makes the 1017 readily transportable. The instrument's outstanding stability v temperature and time performance is because of the use of special computer-selected reference diodes and resistor technology. The low-thermal emf terminals reduce errors when working with microvolt signals. Digital deviation control allows the output to be increased and decreased in % terms from 0 to ±0.999%. This provides a direct readout of error and simplifies the recording results for calibration certificates. It enables the user to see immediately whether the unit under test is within specification. The 1017 is suitable for calibrating and simulating a wide range of instruments including thermocouples, transducers, 4 - 20 mA and 0 - 10 V transmitters and platinum resistance thermometers. DC voltage 10nV to 100V DC current 100nA to 100mA Resistance 10MΩ to 10kΩ Accuracy 0.0005% (50 ppm) 1 ppm setting resolution Noise <2 ppm (0.1 to 1Hz) Stability <5 ppm/day, <25 ppm/year Deviation control - voltage and current Battery or mains operation Dimensions 290 x 250 x 110 mm Weight 2.4kg
1 products found
JPY: 518,000
USD: 3,223.00
-
[Out of stock]Time Electronic 1024 Current & Voltage Calibrator 0 → 100 mA 1024
Time Electronics Model 1024 DC Current Calibrator with Null Measuring Facility. Time Electronics 1024 is a readily portable solid state battery-powered calibrator suitable for laboratory, field or industrial use. It incorporates Time Electronics' well-proven circuit techniques. Additionally, the null balance system enables the 1024 to be used for making accurate current measurement. Operation is by backing the current source output against the current to be measured, with the difference being displayed on a sensitive centre zone null meter. At the null point, there is no voltage drop across the 1024. Applications include calibration and testing of current-sensitive transducers, calibration and linearity tests (on digital and electronic current meters) and semiconductor parameter measurements (such as diode conduction voltages at specified current levels). Simply plugging the 1024 into a mains supply will charge its batteries - a front panel indicator serves as a supply on/off display and monitors the battery supply condition. Up to 100mA output 0.02% accuracy 10 ppm/hr stability Null facility Portable Dimensions 220(L) x 160(H) x 200(D) mm Weight 3.3kg Battery and mains operation
1 products found
JPY: 489,000
USD: 3,042.56