3-3390-12 [Discontinued]ESCO Biohazard Safety Cabinet (ClassII Type A2) AC2-3 N7 G4 10"(3ft) AC2-3N7 G4 10"
คุณลักษณะ
- NSF/ANSI49 compliant (2011610, 2011612).
- A 7-inch touchscreen control panel graphically displays important safety information on a single screen.
- Uses high-performance ULPA filter for ISO Class 3 cleanliness.
- Equipped with a wind speed sensor to monitor airflow in real time to ensure safety
- LED allows brightness adjustment to reduce glare.
- Germicidal lamps have a timer type off function to prevent unnecessary wear and tear.
ข้อมูลจําเพาะ
- Model No.: AC2-3 N7 G4 10"(3ft)
- Size (mm): 1035 x 850 x 1975
- Work Area Dimension (mm): 915 x 610 x 660
- Wind velocity: inlet velocity/approx. 0.53 m/sec, downward flow/approx. 0.3 m/sec
- Average illuminance: > 900 lux (measured at work plane level)
- Filter Material: Downdraft/Exhaust Filter/ULPA Filter (Downdraft/Exhaust Filter)
- Filter performance: particle collection rate of 99.999% or more
- Internal Outlet: Drip-Proof Embedded Type 2-Port E with Poles x 2 (1 for Each Side Wall)
- Exterior: Galvanized Steel Plate 1.2 mm Thickness (Antibacterial (ISOCIDETM) Coating Finish)
- Interior: Made of Stainless Steel (SUS-304) 1.5 mm Thickness (Workbench Can Be Removed and Cleaned)
- Power: 100 VAC 50/60Hz
- Weight: 203 kg
- *Shipping, delivery, installation and assembly costs are required separately. Please contact us.
- *Periodic maintenance is required depending on the germs handled. Please contact us for details.
| หมายเลขใบสั่ง | 3-3390-12 | |
|---|---|---|
| หมายเลขแบบจําลอง | AC2-3N7 G4 10" | |
| ราคามาตรฐาน |
JPY: 1,440,000
USD: 9,026.52
Excange rate 1USD= 159.53JPY
Valid price in Japan |
|
| ปริมาณ | 1set | |
|
|
||
| หุ้นในประเทศญี่ปุ่น | - | |
ผลิตภัณฑ์ที่เกี่ยวข้อง (ขนาดที่แตกต่างกัน, ข้อมูลจําเพาะ,ผลิตภัณฑ์ตัวเลือก ฯลฯ)
| รูปภาพผลิตภัณฑ์ | หมายเลขใบสั่ง | ชื่อ | หมายเลขแบบจําลอง | ปริมาณ | ราคามาตรฐาน | ราคาที่ถูกต้องในประเทศญี่ปุ่น | หุ้น [หุ้นซัพพลายเออร์] |
|
|---|---|---|---|---|---|---|---|---|
![]() |
3-3390-12 | [Discontinued]ESCO Biohazard Safety Cabinet (ClassII Type A2) AC2-3 N7 G4 10"(3ft) AC2-3N7 G4 10" | AC2-3N7 G4 10" |
|
1set | JPY: 1,440,000 | USD: 9,026.52 |
-
|
![]() |
3-3390-13 | [Discontinued]ESCO Biohazard Safety Cabinet (ClassII Type A2) AC2-4 N7 G4 10"(4ft) AC2-4N7 G4 10" | AC2-4N7 G4 10" |
|
1set | JPY: 1,500,000 | USD: 9,402.62 |
-
|
![]() |
3-3390-14 | [Discontinued]ESCO Biohazard Safety Cabinet (ClassII Type A2) AC2-5 N7 G4 10"(5ft) AC2-5N7 G4 10" | AC2-5N7 G4 10" |
|
1set | JPY: 1,840,000 | USD: 11,533.88 |
-
|
![]() |
3-3390-15 | [Discontinued]ESCO Biohazard Safety Cabinet (ClassII Type A2) AC2-6 N7 G4 10"(6ft) AC2-6N7 G4 10" | AC2-6N7 G4 10" |
|
1set | JPY: 1,900,000 | USD: 11,909.99 |
-
|
ผลิตภัณฑ์ที่เกี่ยวข้อง
แค็ตตาล็อกผลิตภัณฑ์
| ชื่อแค็ตตาล็อก | หน้า |
|---|---|
| AS ONE Catalog 2025 [Instruments for Laboratory] | 918 |
| SANIFOODS Catalog 2024 [Inspection and Sanitation] | 70 |
| ASPURE Catalog 2025>2026 [Supplies for Clean Environment] | 166 |
| ASONE Catalog 2022 [Facility & Equipment for Labolatory] | 326 |
| NAVIS Catalog 2024 [Supplies for Nursing and Medical] | 889 |
![[Discontinued]ESCO Biohazard Safety Cabinet (ClassII Type A2) AC2-3 N7 G4 10"(3ft) AC2-3N7 G4 10"](https://aimg.as-1.co.jp/c/3/3390/12/03339013.jpg?v=03790be0f2ba82c1280907a7033cf49dabaaa7c1)
![[Discontinued]ESCO Biohazard Safety Cabinet (ClassII Type A2) AC2-3 N7 G4 10"(3ft) AC2-3N7 G4 10"](https://aimg.as-1.co.jp/c/3/3390/12/03339012b.jpg?v=03790be0f2ba82c1280907a7033cf49dabaaa7c1)
![[Discontinued]ESCO Biohazard Safety Cabinet (ClassII Type A2) AC2-3 N7 G4 10"(3ft) AC2-3N7 G4 10"](https://aimg.as-1.co.jp/c/3/3390/12/03339012a.jpg?v=03790be0f2ba82c1280907a7033cf49dabaaa7c1)
![[Discontinued]ESCO Biohazard Safety Cabinet (ClassII Type A2) AC2-3 N7 G4 10"(3ft) AC2-3N7 G4 10"](https://aimg.as-1.co.jp/c/3/3390/12/03339012d.jpg?v=03790be0f2ba82c1280907a7033cf49dabaaa7c1)
![[Discontinued]ESCO Biohazard Safety Cabinet (ClassII Type A2) AC2-3 N7 G4 10"(3ft) AC2-3N7 G4 10"](https://aimg.as-1.co.jp/c/3/3390/12/03339012c.jpg?v=03790be0f2ba82c1280907a7033cf49dabaaa7c1)