69-5247-32 Combustion Exhaust Gas Analyzer O2/CO/NO/NO2/SO2 HT-2700N
기능
- Ultra-lightweight and compact, with a color LCD display.
- Measurement of pressure and differential pressure and trend graph display of measured values are possible.
사양
- Display: TFT color LCD switching system (7 lines/4 lines/2 lines)
- Sampling Probe: Insertion Length/300 mm (φ6 mm), Exhaust Gas Temperature/0~650°C, Hose Length/2.7 m
- Power: AC Adapter (100 ~240 VAC, 50/60Hz, 5 VDC, 1200 mA) Lithium Ion Rechargeable Battery (Up to 8 hours continuous operation)
- Size: 112 x 244 x 54 mm
- Weight: about 880 g
- Accessories: AC Adapter (USB Cable Included), Sampling Probe, Drain Pot, SD Card (8GB), Star Filter, Pressure Measuring Hose, ABC Resin Case
- < Measurement Specifications: 5 Components (O2/CO/NO/NO2/SO2) >
- Gas to be measured: O2 (oxygen)
- Measurement Method: Galvanic Battery Type
- Measuring range: 0~21.0vol%
- Accuracy: ±0.3vol%
- Resolution: 0.1vol%
- Response time: 30 seconds or less
- Gas to be measured: CO (carbon monoxide)
- Measuring method: Constant potential electrolytic system
- Measurement range: 0~2000ppm (Maximum allowable range: 10,000 ppm)
- Accuracy: 0~2000ppm/±10ppm or ±5% of measured value, whichever is greater; 2001~ 10,000 ppm/±10% of measured value
- Resolution: 1ppm
- Response time: 0~2000ppm/40 seconds or less, 2001~ 10,000 ppm/60 seconds or less
- Gas to be measured: NO (nitric oxide)
- Measuring method: Constant potential electrolytic system
- Measurement range: 0~1000ppm (Maximum allowable range: 3000ppm)
- Accuracy: 0~1000ppm/±5ppm or ±5% of measured value, whichever is greater, 1001~3000ppm/±10% of measured value
- Resolution: 1ppm
- Response time: 0~1000ppm/40 seconds or less, 1001~3000ppm/60 seconds or less
- Gas to be measured: NO2 (nitrogen dioxide)
- Measuring method: Constant potential electrolytic system
- Measurement range: 0~200ppm (Maximum allowable range: 500ppm)
- Accuracy: 0~200ppm/±10ppm, 201~500ppm/±10% of measured value
- Resolution: 1ppm
- Response time: 0~200ppm/60 seconds or less, 201~500ppm/100 seconds or less
- Gas to be measured: SO2 (sulfur dioxide)
- Measuring method: Constant potential electrolytic system
- Measurement range: 0~2000ppm (Maximum allowable range: 4000ppm)
- Accuracy: 0~2000ppm/±10ppm or ±5% of measured value, whichever is greater; 2001~4000ppm/±10% of measured value
- Resolution: 1ppm
- Response time: 0~2000ppm/60 seconds or less, 2001~4000ppm/100 seconds or less
- *Please check the price in advance as the specifications are subject to change without notice.
패키지 크기:510×170×460 mm [패키지 크기 정보]
| 주문 번호 | 69-5247-32 | |
|---|---|---|
| 모델 번호 | HT-2700N | |
| 표준 가격 |
JPY: 1,740,000
USD: 10,914.57
Excange rate 1USD= 159.42JPY
Valid price in Japan |
|
| 수량 | 1piece | |
| 일본의 주식 |
|
|
| 공급자 재고 |
|
|
다양한 상품군(多樣한) (다른 사이즈,다른 사양,옵션등)
| 제품 이미지 | 주문 번호 | 이름 | 모델 번호 | 수량 | 표준 가격 | 일본에서의 유효 가격 | 재고 [공급자 재고] |
|
|---|---|---|---|---|---|---|---|---|
![]() |
3-9327-11 | Combustion type gas analyser O2/CO2/CO/NO/NO2/SO2 HT-2700N | HT-2700N |
|
1piece | JPY: 2,037,000 | USD: 12,777.57 |
|
![]() |
69-5247-30 | Combustion exhaust gas analyzer O2/CO/CO2 HT-2700N | HT-2700N |
|
1piece | JPY: 1,318,000 | USD: 8,267.47 |
|
![]() |
69-5247-31 | Combustion exhaust gas analyzer O2/high concentration CO/CO2 HT-2700N | HT-2700N |
|
1piece | JPY: 1,400,000 | USD: 8,781.83 |
|
![]() |
69-5247-32 | Combustion Exhaust Gas Analyzer O2/CO/NO/NO2/SO2 HT-2700N | HT-2700N |
|
1piece | JPY: 1,740,000 | USD: 10,914.57 |
|