69-5247-32 Combustion Exhaust Gas Analyzer O2/CO/NO/NO2/SO2 HT-2700N

  • 배송료 별도

기능

  • Ultra-lightweight and compact, with a color LCD display.
  • Measurement of pressure and differential pressure and trend graph display of measured values are possible.

사양

  • Display: TFT color LCD switching system (7 lines/4 lines/2 lines)
  • Sampling Probe: Insertion Length/300 mm (φ6 mm), Exhaust Gas Temperature/0~650°C, Hose Length/2.7 m
  • Power: AC Adapter (100 ~240 VAC, 50/60Hz, 5 VDC, 1200 mA) Lithium Ion Rechargeable Battery (Up to 8 hours continuous operation)
  • Size: 112 x 244 x 54 mm
  • Weight: about 880 g
  • Accessories: AC Adapter (USB Cable Included), Sampling Probe, Drain Pot, SD Card (8GB), Star Filter, Pressure Measuring Hose, ABC Resin Case
  •  
  • < Measurement Specifications: 5 Components (O2/CO/NO/NO2/SO2) >
  • Gas to be measured: O2 (oxygen)
  • Measurement Method: Galvanic Battery Type
  • Measuring range: 0~21.0vol%
  • Accuracy: ±0.3vol%
  • Resolution: 0.1vol%
  • Response time: 30 seconds or less
  • Gas to be measured: CO (carbon monoxide)
  • Measuring method: Constant potential electrolytic system
  • Measurement range: 0~2000ppm (Maximum allowable range: 10,000 ppm)
  • Accuracy: 0~2000ppm/±10ppm or ±5% of measured value, whichever is greater; 2001~ 10,000 ppm/±10% of measured value
  • Resolution: 1ppm
  • Response time: 0~2000ppm/40 seconds or less, 2001~ 10,000 ppm/60 seconds or less
  • Gas to be measured: NO (nitric oxide)
  • Measuring method: Constant potential electrolytic system
  • Measurement range: 0~1000ppm (Maximum allowable range: 3000ppm)
  • Accuracy: 0~1000ppm/±5ppm or ±5% of measured value, whichever is greater, 1001~3000ppm/±10% of measured value
  • Resolution: 1ppm
  • Response time: 0~1000ppm/40 seconds or less, 1001~3000ppm/60 seconds or less
  • Gas to be measured: NO2 (nitrogen dioxide)
  • Measuring method: Constant potential electrolytic system
  • Measurement range: 0~200ppm (Maximum allowable range: 500ppm)
  • Accuracy: 0~200ppm/±10ppm, 201~500ppm/±10% of measured value
  • Resolution: 1ppm
  • Response time: 0~200ppm/60 seconds or less, 201~500ppm/100 seconds or less
  • Gas to be measured: SO2 (sulfur dioxide)
  • Measuring method: Constant potential electrolytic system
  • Measurement range: 0~2000ppm (Maximum allowable range: 4000ppm)
  • Accuracy: 0~2000ppm/±10ppm or ±5% of measured value, whichever is greater; 2001~4000ppm/±10% of measured value
  • Resolution: 1ppm
  • Response time: 0~2000ppm/60 seconds or less, 2001~4000ppm/100 seconds or less
  •  
  • *Please check the price in advance as the specifications are subject to change without notice.
  •  

패키지 크기:510×170×460 mm   [패키지 크기 정보]

주문 번호 69-5247-32
모델 번호 HT-2700N
표준 가격 JPY: 1,740,000 USD: 10,914.57
Excange rate 1USD= 159.42JPY
Valid price in Japan
수량 1piece
일본의 주식
공급자 재고

다양한 상품군(多樣한) (다른 사이즈,다른 사양,옵션등)

제품 이미지 주문 번호 이름 모델 번호 수량 표준 가격 일본에서의 유효 가격 재고
[공급자 재고]
3-9327-11 Combustion type gas analyser O2/CO2/CO/NO/NO2/SO2 HT-2700N HT-2700N
  • 배송료 별도
1piece JPY: 2,037,000 USD: 12,777.57

69-5247-30 Combustion exhaust gas analyzer O2/CO/CO2 HT-2700N HT-2700N
  • 배송료 별도
1piece JPY: 1,318,000 USD: 8,267.47

69-5247-31 Combustion exhaust gas analyzer O2/high concentration CO/CO2 HT-2700N HT-2700N
  • 배송료 별도
1piece JPY: 1,400,000 USD: 8,781.83

69-5247-32 Combustion Exhaust Gas Analyzer O2/CO/NO/NO2/SO2 HT-2700N HT-2700N
  • 배송료 별도
1piece JPY: 1,740,000 USD: 10,914.57

제품 카탈로그

카탈로그 이름 페이지
AS ONE Catalog 2025 [Instruments for Laboratory] 9999