RIKEN KEIKI Co., Ltd.

67-8025-91 (Domestic Sales only in Japan) Simple Stationary Carbon Monoxide Meter Remote Sensor (20 m) 24 VDC Specification (with Traceability Certificate) EC-600-20DC

Fitur

  • For prevention of carbon monoxide poisoning!
  • It's big and easy to see! With the LCD screen shining in 3 colors, it is possible to identify the detection state even if it is far from the display.
  • For preventing carbon monoxide poisoning in control rooms and offices due to CO gas generated in steel works!
  • For prevention of poisoning accidents caused by leakage of CO gas in research facilities of various factories, universities, etc.!
  • With the remote sensor attached, the sensor can be installed in a place where there is a risk of leakage and the concentration value can be checked in another safe area.
  • This product comes with a traceability certificate. Breakdown of attached documents: gas inspection report (acceptance certificate issued by gas manufacturer), traceability system (traceability system diagram for gas production), traceability chart (traceability system diagram for equipment and measuring instruments)

Spec

  • Target gas: Carbon monoxide
  • Detection principle: Constant potential electrolytic type
  • Intensity Display: LCD Digital Display (3-Digit, 7-Segment/Green, Orange, Red 3 Color Backlight)
  • Detection range (ppm): 0-150
  • Display resolution (ppm): 1
  • Detection method: Diffusion type
  • Alarm setting: 50ppm (1st)/100ppm (2nd)
  • [Standard setting]
  • Alarm delay time: Within 60 seconds after introducing gas with 1.6 times the concentration of the alarm point.
  • Gas alarm type: two-stage alarm (H-HH)
  • Gas alarm display: 1st/Density display and backlight on (orange), buzzer, 2nd/Density display and backlight on (red), buzzer
  • Gas alarm operation: self-holding
  • Gas alarm contact: non-voltage contact 1a/normally non-energized (energized at alarm)
  • Failure alarm and self-diagnosis: System error/sensor connection error
  • Failure Warning Display: Contents Display and Backlight Flashing (Orange), Buzzer
  • Failure alarm operation: automatic return
  • Transmission Specifications: 4~20 mA DC (Non-Insulated, Load Resistance 300 Ω or Less)
  • Detector Cable: Dedicated Remote Cable (20 m)
  • Power: 24 VDC ±10%
  • Power consumption: Up to 3W
  • Operating temperature range: 0~40°C (without sudden change)
  • Operating humidity range: 90%RH or less (no condensation)
  • Structure: Wall mounted type/sensor integrated type
  • External Dimensions (mm): Body/Approx. 80 (W) x 120 (H) x 35.5 (D), Remote Sensor/Approx. 40 (W) x 96 (H) x 35.5 (D) (Excluding Protrusion)
  • Weight (g): Body/Approx. 180, Remote Sensor/Approx. 55 (Excluding Cable)
  •  
Perintah No. 67-8025-91
Model No. EC-600-20DC
Harga standar JPY: - USD: -
Excange rate 1USD= 160.72JPY
Valid price in Japan
Kuantitas 1unit
Saham di Jepang
Saham Pemasok

Variasi produk (ukuran berbeda, spesifikasi berbeda, produk opsional, dll)

Gambar produk Perintah No. Nama Model No. Kuantitas Harga standar Harga valid di Jepang Stok
[Saham Pemasok]
67-8025-78 (Domestic Sales only in Japan) Simple Stationary Carbon Monoxide Meter Integrated Type 100 VAC Specification (with Traceability Certificate) EC-600-00AC EC-600-00AC 1unit JPY: - USD: -

67-8025-79 (Domestic Sales only in Japan) Simple Stationary Carbon Monoxide Meter Integrated Type 24 VDC Specification (with Traceability Certificate) EC-600-00DC EC-600-00DC 1unit JPY: - USD: -

67-8025-80 (Domestic Sales only in Japan) Simple Stationary Carbon Monoxide Meter Integrated Dry Battery Specification (with Traceability Certificate) EC-600-00BT EC-600-00BT 1unit JPY: - USD: -

67-8025-81 (Domestic Sales only in Japan) Simple Stationary Carbon Monoxide Meter Remote Sensor (3 m) 100 VAC Specification (with Traceability Certificate) EC-600-03AC EC-600-03AC 1unit JPY: - USD: -

67-8025-82 (Domestic Sales only in Japan) Simple Stationary Carbon Monoxide Meter Remote Sensor (3 m) 24 VDC Specification (with Traceability Certificate) EC-600-03DC EC-600-03DC 1unit JPY: - USD: -

67-8025-83 (Domestic Sales only in Japan) Simple Stationary Carbon Monoxide Meter Remote Sensor (3 m) Dry Battery Specification (with Traceability Certificate) EC-600-03BT EC-600-03BT 1unit JPY: - USD: -

67-8025-84 (Domestic Sales only in Japan) Simple Stationary Carbon Monoxide Meter Remote Sensor (5 m) 100 VAC Specification (with Traceability Certificate) EC-600-05AC EC-600-05AC 1unit JPY: - USD: -

67-8025-85 (Domestic Sales only in Japan) Simple Stationary Carbon Monoxide Meter Remote Sensor (5 m) 24 VDC Specification (with Traceability Certificate) EC-600-05DC EC-600-05DC 1unit JPY: - USD: -

67-8025-86 (Domestic Sales only in Japan) Simple Stationary Carbon Monoxide Meter Remote Sensor (5 m) Dry Battery Specification (with Traceability Certificate) EC-600-05BT EC-600-05BT 1unit JPY: - USD: -

67-8025-87 (Domestic Sales only in Japan) Simple Stationary Carbon Monoxide Meter Remote Sensor (10 m) 100 VAC Specification (with Traceability Certificate) EC-600-10AC EC-600-10AC 1unit JPY: - USD: -

67-8025-88 (Domestic Sales only in Japan) Simple Stationary Carbon Monoxide Meter Remote Sensor (10 m) 24 VDC Specification (with Traceability Certificate) EC-600-10DC EC-600-10DC 1unit JPY: - USD: -

67-8025-89 (Domestic Sales only in Japan) Simple Stationary Carbon Monoxide Meter Remote Sensor (10 m) Dry Battery Specification (with Traceability Certificate) EC-600-10BT EC-600-10BT 1unit JPY: - USD: -

67-8025-90 (Domestic Sales only in Japan) Simple Stationary Carbon Monoxide Meter Remote Sensor (20 m) 100 VAC Specification (with Traceability Certificate) EC-600-20AC EC-600-20AC 1unit JPY: - USD: -

67-8025-91 (Domestic Sales only in Japan) Simple Stationary Carbon Monoxide Meter Remote Sensor (20 m) 24 VDC Specification (with Traceability Certificate) EC-600-20DC EC-600-20DC 1unit JPY: - USD: -

67-8025-92 (Domestic Sales only in Japan) Simple Stationary Carbon Monoxide Meter Remote Sensor (20 m) Dry Battery Specification (with Traceability Certificate) EC-600-20BT EC-600-20BT 1unit JPY: - USD: -