[Tedea Huntleigh] AllProducts
Lab Instruments & Supplies
-
Electronic/Electrical Parts and Controll Equipments
-
Tedea Huntleigh Compression Load Cell 0.3kg, 15V dc, IP66 1004-00.3-JW00-RS
Low Capacity Single Point Aluminium. Output impendence 350Ω Safe overload 150% rated capacity Ultimate overload 250% rated capacity Cable type 4 Wire; 28 AWG; Spiral Shield; PVC Jacket. Low capacity, high precision, aluminium, single point load cell. A special humidity-resistant protective coating ensures long-term reliability. 200 x 200mm maximum platform size Up to 30 000 weighing increments Dimensions 110x33x10mm. Applications: Include Low level force measurement, postal, counting or jewellery scales, analytical balances.
1 products found
JPY: 23,200
USD: 145.43
-
Tedea Huntleigh Compression & Tension Load Cell 300kg, 15V dc, IP67 0615-0300-G000-RS
Tedea Huntleigh Compression ; Tension Load Cell "S" Beam Type 200/300kg. Features and Benefits:. Output impendence 350Ω Input Impedance 400 ±20Ω Safe overload 150% rated capacity Ultimate overload 300% rated capacity For use in tension and compression 6 wire (sense) circuit Bridge signal conditioners available separately For Output signal conditioners see (stock no. ; 455-5043 455-5043 ) Dimensions 62 x 80 x 18mm The additional sense wires compensate for changes in lead resistance due to temperature changes and/or cable extension. Typical Applications:. Force measurement, material testing machines, conversion of mechanical scales to electronic, hanging scales, hoppers. FAQs:. What thread does it have? This is 1/2 Inch UNF
1 products found
JPY: 48,500
USD: 304.02
-
Tedea Huntleigh Compression Load Cell 20kg, 15V dc, IP66 0240-0020-E002
Single Point, Oil Damped. Output impendence 350Ω Safe overload 150% rated capacity Ultimate overload 300% rated capacity. A single point, 20kg load cell designed for use in high speed check weighers/fillers or applications under continuous shock and vibration conditions. Can be installed within 1° of the horizontal IP rating IP66 Dimensions 220x115x80mm For Output signal conditioners see stock no. ; 455-5043 455-5043
1 products found
JPY: 177,000
USD: 1,109.51
-
Tedea Huntleigh Compression & Tension Load Cell 500kg, 15V dc, IP67 0616-0500-F000-RS
Tedea Huntleigh Compression ; Tension Load Cell "S" Beam Type 200/300kg. Features and Benefits:. Output impendence 350Ω Input Impedance 400 ±20Ω Safe overload 150% rated capacity Ultimate overload 300% rated capacity For use in tension and compression 6 wire (sense) circuit Bridge signal conditioners available separately For Output signal conditioners see (stock no. ; 455-5043 455-5043 ) Dimensions 62 x 80 x 18mm The additional sense wires compensate for changes in lead resistance due to temperature changes and/or cable extension. Typical Applications:. Force measurement, material testing machines, conversion of mechanical scales to electronic, hanging scales, hoppers. FAQs:. What thread does it have? This is 1/2 Inch UNF
1 products found
JPY: 79,800
USD: 500.22
-
Tedea Huntleigh Compression Load Cell 100kg, 15V dc, IP68 0355-0100-G300-RS
Cantilever - Stainless Steel. Compensated Temperature Range -10 to +40°C Output Impedance 350 +/- 3Ω Termination Type: Cable Ultimate Overload: 300% of Rated Load. Low profile, welded stainless steel cells hermetically sealed to IP67 for use in harsh environments. Suitable for platform scales, hopper and tank weighing, general process weighing, test rigs and general force measurements Mounting via 3 x 8mm holes Connection via 3m 6-core screened cable Dimensions 120 x 32mm dia.
1 products found
JPY: 75,600
USD: 473.89
-
Tedea Huntleigh Compression Load Cell 250kg, 15V dc, IP68 0355-0250-G300-RS
Cantilever - Stainless Steel. Compensated Temperature Range -10 to +40°C Output Impedance 350 +/- 3Ω Termination Type: Cable Ultimate Overload: 300% of Rated Load. Low profile, welded stainless steel cells hermetically sealed to IP67 for use in harsh environments. Suitable for platform scales, hopper and tank weighing, general process weighing, test rigs and general force measurements Mounting via 3 x 8mm holes Connection via 3m 6-core screened cable Dimensions 120 x 32mm dia.
1 products found
JPY: 75,200
USD: 471.39
-
Tedea Huntleigh Compression Load Cell 1000kg, 15V dc, IP68 MODEL3510-1000-C2
Shear Beam - Stainless Steel. Compensated Temperature Range -10 to +40°C Output Impedance 350 +/- 3Ω Termination Type: Cable Ultimate Overload: 300% of Rated Load. Rugged, low profile, welded unit designed to work in harsh environments. Stainless steel units, sealed to IP68, suitable for use in pallet weighers, hopper and tank weighing Fitted with 5m 6-core shielded cable Dimensions 32 x 32 x 130mm
1 products found
JPY: 93,900
USD: 588.60
-
Tedea Huntleigh Compression & Tension Load Cell 200kg, 15V dc, IP67 0615-0200-G000-RS
Tedea Huntleigh Compression ; Tension Load Cell "S" Beam Type 200/300kg. Features and Benefits:. Output impendence 350Ω Input Impedance 400 ±20Ω Safe overload 150% rated capacity Ultimate overload 300% rated capacity For use in tension and compression 6 wire (sense) circuit Bridge signal conditioners available separately For Output signal conditioners see (stock no. ; 455-5043 455-5043 ) Dimensions 62 x 80 x 18mm The additional sense wires compensate for changes in lead resistance due to temperature changes and/or cable extension. Typical Applications:. Force measurement, material testing machines, conversion of mechanical scales to electronic, hanging scales, hoppers. FAQs:. What thread does it have? This is 1/2 Inch UNF
1 products found
JPY: 48,500
USD: 304.02
-
Tedea Huntleigh Compression Load Cell 3kg, 15V dc, IP66 1042-0003-F000-RS
Low Profile Aluminium. Compensated Temperature Range -10 to +40°C Output Impedance 350 +/- 3Ω Termination Type: Cable Ultimate Overload: 300% of Rated Load. 1042 series low profile single point load cell designed for direct mounting of low cost weighing platforms. Has a humidity resistant protective coating, which assures long term stability over the entire compensated temperature range. Dimensions: 20 x 40 x 150mm (1 to 30kg); 25.2 x 40 x 150mm (50 to 100kg) For Output signal conditioners see (stock no. ; 455-5043 455-5043 )
1 products found
JPY: 30,300
USD: 189.93
-
Tedea Huntleigh Compression Load Cell 5kg, 15V dc, IP66 1042-0005-F000-RS
Low Profile Aluminium. Compensated Temperature Range -10 to +40°C Output Impedance 350 +/- 3Ω Termination Type: Cable Ultimate Overload: 300% of Rated Load. 1042 series low profile single point load cell designed for direct mounting of low cost weighing platforms. Has a humidity resistant protective coating, which assures long term stability over the entire compensated temperature range. Dimensions: 20 x 40 x 150mm (1 to 30kg); 25.2 x 40 x 150mm (50 to 100kg) For Output signal conditioners see (stock no. ; 455-5043 455-5043 )
1 products found
JPY: 30,200
USD: 189.31
-
Tedea Huntleigh Compression Load Cell 7kg, 15V dc, IP66 1042-0007-F000-RS
Low Profile Aluminium. Compensated Temperature Range -10 to +40°C Output Impedance 350 +/- 3Ω Termination Type: Cable Ultimate Overload: 300% of Rated Load. 1042 series low profile single point load cell designed for direct mounting of low cost weighing platforms. Has a humidity resistant protective coating, which assures long term stability over the entire compensated temperature range. Dimensions: 20 x 40 x 150mm (1 to 30kg); 25.2 x 40 x 150mm (50 to 100kg) For Output signal conditioners see (stock no. ; 455-5043 455-5043 )
1 products found
JPY: 31,400
USD: 196.83
-
Tedea Huntleigh Compression Load Cell 30kg, 15V dc, IP66 1042-0030-F000-RS
Low Profile Aluminium. Compensated Temperature Range -10 to +40°C Output Impedance 350 +/- 3Ω Termination Type: Cable Ultimate Overload: 300% of Rated Load. 1042 series low profile single point load cell designed for direct mounting of low cost weighing platforms. Has a humidity resistant protective coating, which assures long term stability over the entire compensated temperature range. Dimensions: 20 x 40 x 150mm (1 to 30kg); 25.2 x 40 x 150mm (50 to 100kg) For Output signal conditioners see (stock no. ; 455-5043 455-5043 )
1 products found
JPY: 30,900
USD: 193.69
-
Tedea Huntleigh Compression Load Cell 75kg, 15V dc, IP66 1042-0075-F000-RS
Low Profile Aluminium. Compensated Temperature Range -10 to +40°C Output Impedance 350 +/- 3Ω Termination Type: Cable Ultimate Overload: 300% of Rated Load. 1042 series low profile single point load cell designed for direct mounting of low cost weighing platforms. Has a humidity resistant protective coating, which assures long term stability over the entire compensated temperature range. Dimensions: 20 x 40 x 150mm (1 to 30kg); 25.2 x 40 x 150mm (50 to 100kg) For Output signal conditioners see (stock no. ; 455-5043 455-5043 )
1 products found
JPY: 30,200
USD: 189.31
-
Tedea Huntleigh Compression Load Cell 100kg, 15V dc, IP66 1042-0100-F000-RS
Low Profile Aluminium. Compensated Temperature Range -10 to +40°C Output Impedance 350 +/- 3Ω Termination Type: Cable Ultimate Overload: 300% of Rated Load. 1042 series low profile single point load cell designed for direct mounting of low cost weighing platforms. Has a humidity resistant protective coating, which assures long term stability over the entire compensated temperature range. Dimensions: 20 x 40 x 150mm (1 to 30kg); 25.2 x 40 x 150mm (50 to 100kg) For Output signal conditioners see (stock no. ; 455-5043 455-5043 )
1 products found
JPY: 31,400
USD: 196.83
-
Tedea Huntleigh Compression Load Cell 100kg, 15V dc, IP65 1250-0100-F000-RS
High Capacity Aluminium. 1250 series high capacity single point load cell designed for direct mounting of large platforms. Has a humidity-resistant protective coating, assuring long term stability over the compensated temperature range.
1 products found
JPY: 71,500
USD: 448.19
-
Tedea Huntleigh Compression Load Cell 500kg, 15V dc, IP65 1250-0500-F000-RS
High Capacity Aluminium. 1250 series high capacity single point load cell designed for direct mounting of large platforms. Has a humidity-resistant protective coating, assuring long term stability over the compensated temperature range.
1 products found
JPY: 72,000
USD: 451.33
-
Tedea Huntleigh Compression Load Cell 50kg, 15V dc, IP65 1250-0050-F000-RS
High Capacity Aluminium. 1250 series high capacity single point load cell designed for direct mounting of large platforms. Has a humidity-resistant protective coating, assuring long term stability over the compensated temperature range.
1 products found
JPY: 71,700
USD: 449.45
-
Tedea Huntleigh Compression Load Cell 1000kg, 15V dc, IP65 1250-1000-F000-RS
High Capacity Aluminium. 1250 series high capacity single point load cell designed for direct mounting of large platforms. Has a humidity-resistant protective coating, assuring long term stability over the compensated temperature range.
1 products found
JPY: 75,100
USD: 470.76
-
[Discontinued]Tedea Huntleigh Compression Load Cell 0.6kg, 15V dc, IP66 1004-00.6-JW00-RS
Low Capacity Single Point Aluminium. Output impendence 350Ω Safe overload 150% rated capacity Ultimate overload 250% rated capacity Cable type 4 Wire; 28 AWG; Spiral Shield; PVC Jacket. Low capacity, high precision, aluminium, single point load cell. A special humidity-resistant protective coating ensures long-term reliability. 200 x 200mm maximum platform size Up to 30 000 weighing increments Dimensions 110x33x10mm. Applications: Include Low level force measurement, postal, counting or jewellery scales, analytical balances.
1 products found
JPY: 18,900
USD: 118.47