[TOKYO RIKAKIKAI CO., LTD.]Physical Property Measurement
Filters
-
Pressure gauge NCC-P2
1 products found
JPY: 60,000
USD: 373.32
-
Flowmeter, 2 ~ 30 L/min and others
2 products found
JPY: 72,000-
USD: 447.98-
-
Pressure gauge 0 ~ 0.25 MPa CA-P2
Pressure management is possible when pressure loss at the circulation destination is considered or when the minimum pressure in the circulation path is limited. (Only for water and low-temperature heat media, pure water is not allowed, no condensation is required, and the operating temperature range is 0~60°C.)
1 products found
JPY: 26,000
USD: 161.77
-
Flow meter 2 ~ 30 L/min for checking circulating water CA-F2
It can be used to check whether circulating water is flowing reliably during operation of the device and how much flow is present. (Water, colourless thermal medium for low temperature only, pure water not allowed, non-condensing, working temperature range 5~50°C)
1 products found
JPY: 56,000
USD: 348.43
-
Pressure switch CA-PS4
If a pressure abnormality is detected, such as when the piping is clogged or when the back pressure of the circulation destination is abnormally high, the circulation pump is stopped, the alarm lamp is turned on, and an alarm is output (see. Water, heat medium for low temperature only, no pure water, no condensation, operating temperature range -20~120°C
1 products found
JPY: 54,000
USD: 335.99
-
Flow rate switch 2 ~ 30 L/min CA-FS2
When the flow rate decreases due to back pressure or water leakage in the piping, the circulating pump is stopped and the alarm lamp is turned on to output the alarm (. Water, heat medium for low temperature only, no pure water, no condensation, operating temperature range -5~60°C
1 products found
JPY: 114,000
USD: 709.31
-
Pressure gauge 0 ~ 0.98 MPa CA-P
Pressure management is possible when pressure loss at the circulation destination is considered or when the minimum pressure in the circulation path is limited. (Water, heat medium for low temperature only, no pure water, no condensation, working temperature range 0~60°C)
1 products found
JPY: 26,000
USD: 161.77
-
Flowmeter 2 ~ 30 L/min for checking brine (fluid) CA-F
It can be used to check whether the brine (liquid) is flowing reliably during the operation of the device and the flow rate. (Water, colourless thermal medium for low temperature only, pure water not allowed, non-condensing, working temperature range 5~50°C)
1 products found
JPY: 57,000
USD: 354.65
-
Pressure gauge set (for special heating media)
Can be used to measure pressure when circulating pure water, silicon oil, etc.
1 products found
JPY: 65,000
USD: 404.43
-
[Discontinued]Photostability testing machine LST-2010
Control illuminance, temperature, humidity, and near-ultraviolet rays for light resistance and environmental testing of foods, chemicals, and raw materials. Illuminance can be adjusted up to 17000Lx, temperature can be adjusted up to 60°C, and humidity can be adjusted up to 75%RH, providing high accuracy and reproducibility for light resistance and environmental testing of foods, chemicals, and raw materials. Illuminance is continuously dimmed by the light sensor, so there is little loss of illumination due to deterioration of the light source lamp and it is stable.
Since the air volume can be adjusted, powdery samples can also be used.1 products found
JPY: 3,980,000
USD: 24,763.56