HODAKA Co., Ltd.

69-5247-32 Combustion Exhaust Gas Analyzer O2/CO/NO/NO2/SO2 HT-2700N

  • Shipping fee extra

Features

  • Ultra-lightweight and compact, with a color LCD display.
  • Measurement of pressure and differential pressure and trend graph display of measured values are possible.

Spec

  • Display: TFT color LCD switching system (7 lines/4 lines/2 lines)
  • Sampling Probe: Insertion Length/300 mm (φ6 mm), Exhaust Gas Temperature/0~650°C, Hose Length/2.7 m
  • Power: AC Adapter (100 ~240 VAC, 50/60Hz, 5 VDC, 1200 mA) Lithium Ion Rechargeable Battery (Up to 8 hours continuous operation)
  • Size: 112 x 244 x 54 mm
  • Weight: about 880 g
  • Accessories: AC Adapter (USB Cable Included), Sampling Probe, Drain Pot, SD Card (8GB), Star Filter, Pressure Measuring Hose, ABC Resin Case
  •  
  • < Measurement Specifications: 5 Components (O2/CO/NO/NO2/SO2) >
  • Gas to be measured: O2 (oxygen)
  • Measurement Method: Galvanic Battery Type
  • Measuring range: 0~21.0vol%
  • Accuracy: ±0.3vol%
  • Resolution: 0.1vol%
  • Response time: 30 seconds or less
  • Gas to be measured: CO (carbon monoxide)
  • Measuring method: Constant potential electrolytic system
  • Measurement range: 0~2000ppm (Maximum allowable range: 10,000 ppm)
  • Accuracy: 0~2000ppm/±10ppm or ±5% of measured value, whichever is greater; 2001~ 10,000 ppm/±10% of measured value
  • Resolution: 1ppm
  • Response time: 0~2000ppm/40 seconds or less, 2001~ 10,000 ppm/60 seconds or less
  • Gas to be measured: NO (nitric oxide)
  • Measuring method: Constant potential electrolytic system
  • Measurement range: 0~1000ppm (Maximum allowable range: 3000ppm)
  • Accuracy: 0~1000ppm/±5ppm or ±5% of measured value, whichever is greater, 1001~3000ppm/±10% of measured value
  • Resolution: 1ppm
  • Response time: 0~1000ppm/40 seconds or less, 1001~3000ppm/60 seconds or less
  • Gas to be measured: NO2 (nitrogen dioxide)
  • Measuring method: Constant potential electrolytic system
  • Measurement range: 0~200ppm (Maximum allowable range: 500ppm)
  • Accuracy: 0~200ppm/±10ppm, 201~500ppm/±10% of measured value
  • Resolution: 1ppm
  • Response time: 0~200ppm/60 seconds or less, 201~500ppm/100 seconds or less
  • Gas to be measured: SO2 (sulfur dioxide)
  • Measuring method: Constant potential electrolytic system
  • Measurement range: 0~2000ppm (Maximum allowable range: 4000ppm)
  • Accuracy: 0~2000ppm/±10ppm or ±5% of measured value, whichever is greater; 2001~4000ppm/±10% of measured value
  • Resolution: 1ppm
  • Response time: 0~2000ppm/60 seconds or less, 2001~4000ppm/100 seconds or less
  •  
  • *Please check the price in advance as the specifications are subject to change without notice.
  •  

Package size:510×170×460 mm   [About Package size]

Order No. 69-5247-32
Model No. HT-2700N
Standard price JPY: 1,740,000 USD: 10,914.57
Excange rate 1USD= 159.42JPY
Valid price in Japan
Quantity 1piece
Stock in Japan
Supplier Stock

Product Variations (Different Sizes, Specifications, Optional Products, etc.)

Product image Order No. Name Model No. Quantity Standard price Valid price in Japan Stock
[Supplier Stock]
3-9327-11 Combustion type gas analyser O2/CO2/CO/NO/NO2/SO2 HT-2700N HT-2700N
  • Shipping fee extra
1piece JPY: 2,037,000 USD: 12,777.57

69-5247-30 Combustion exhaust gas analyzer O2/CO/CO2 HT-2700N HT-2700N
  • Shipping fee extra
1piece JPY: 1,318,000 USD: 8,267.47

69-5247-31 Combustion exhaust gas analyzer O2/high concentration CO/CO2 HT-2700N HT-2700N
  • Shipping fee extra
1piece JPY: 1,400,000 USD: 8,781.83

69-5247-32 Combustion Exhaust Gas Analyzer O2/CO/NO/NO2/SO2 HT-2700N HT-2700N
  • Shipping fee extra
1piece JPY: 1,740,000 USD: 10,914.57