64-1032-68 [Discontinued]High-pressure steam Sterilization Unit STS244FA
Features
- After sterilizing the agar medium, the medium can be kept warm within the range of 45°C to 80°C until dispensing, eliminating the problem of solidifying the sterilized medium.
- The microcomputer stores three sterilization patterns. Each time the pattern selection switch is pressed, the respective pattern is displayed, and the operation is simply performed by pressing the start switch.
- Sterilization (121°C, 15 minutes) → Natural cooling → Warming (50°C)
- Sterilization (121°C, 15 minutes) → Natural cooling
- Sterilization (121°C, 20 minutes) → Natural cooling
- Sterilization conditions other than the storage pattern can be freely set with the up/down switch.
- Selectable Sterilization Temperature Range 105°C~123°C
- Selectable Sterilization Time Range 1 min ~999 min (with continuous operation)
- Selectable Insulating Temperature Range 45°C~80°C
- Insulating Time 20 hours Fixed (can be removed prematurely)
- Sterilization time can be set digitally, remaining time can be displayed digitally, and continuous operation can be set.
- Sterilization temperature
- High performance type adopting time integration control system.
- When an abnormality occurs, the error detection circuit operates, and it has a self-diagnosis function that indicates an error with an alarm.
- An exhaust bottle that is easy to see inside is stored in the front of the main body.
Spec
- Sterilization Temperature Range : 105 °C to 123 °C (Variable type, one-touch temperature setting system)
- Thermal Temperature Range: 45 °C to 80 °C (Variable type, one-touch temperature setting system)
- Safety valve operating pressure: 0.157 MPa
- Can Body material: Stainless Steel (SUS304)
- Sterilization timer: 1 minute digital display, 999 minutes to, remaining time display method, continuous Operation possible
- Thermometer: Digital Display 5 °C, to 127 °C (Lo Display for 4 °C and Less)
- Pressure gauge: 0 MPa to 0.4 MPa
- Safety and Alarm Devices: Pressure Safety Valve, Overpressure Prevention Switch, Leakage Breaker, Empty Heating Prevention Device, Error Indication (Empty heater, sensor disconnection, overtemperature, overcooling, overpressure)
- Type of pressure vessel: simple pressure vessel
- external dimensions ( mm ) : W 385 x D 485 x H 845
- Can inner size (capacity): φ 240 mm x H 450 mm (20 L)
- power supply (50Hz/60Hz): AC100V 15 A
- Power Consumption ( kW ) : 1.5
- Mass (kg): 43
- Accessories: Sterilization Basket 2 pieces, Exhaust Bottle 1 piece, Grounding Adapter 1 piece, Drain Hose 1 piece, duckboard 1 piece
Package size:600×620×1040 mm 47.3 kg [About Package size]
| Order No. | 64-1032-68 | |
|---|---|---|
| Model No. | STS244FA | |
| Standard price |
JPY: -
USD: -
Excange rate 1USD= 159.53JPY
Valid price in Japan |
|
| Quantity | 1unit | |
|
|
||
| Stock in Japan | - | |
Product Variations (Different Sizes, Specifications, Optional Products, etc.)
| Product image | Order No. | Name | Model No. | Quantity | Standard price | Valid price in Japan | Stock [Supplier Stock] |
|
|---|---|---|---|---|---|---|---|---|
![]() |
64-1032-68 | [Discontinued]High-pressure steam Sterilization Unit STS244FA | STS244FA | 1unit | JPY: - | USD: - |
-
|
|
![]() |
64-1032-69 | [Discontinued]High-pressure steam Sterilization Unit STS306FA | STS306FA | 1unit | JPY: - | USD: - |
-
|
![[Discontinued]High-pressure steam Sterilization Unit STS244FA](https://aimg.as-1.co.jp/c/64/1032/68/64103268.jpg?v=03790be0f2ba82c1280907a7033cf49dabaaa7c1)