RIKEN KEIKI Co., Ltd.

63-7822-47 (Domestic Sales only in Japan) Hazardous Gas Detector for Manhole/Pit Work GX-2100 Type EJ [Oxygen/Hydrogen Sulfide (JIS Adapted)] GX-2100

Features

  • Improved work efficiency and safety by adopting a new detection system!
  • 3-year sensor warranty with new high-performance R sensor (However, a manufacturer inspection more than once a year is a condition.)
  • Reliable and safe design! < Gas Detector > (1) Non-ignition explosion-proof structure makes it safe even in dangerous places (can be used only in Zone 2) (2) Equipped with a balancer, the sensor is exposed from the water surface and continues to detect gas even if it is dropped on the water surface (3) Shock resistance (clears 10 m drop test) (4) Easy-to-use and enhanced functionality (density display, alarm function, LED light installed in the detector)

Spec

  • Target gas: Oxygen and hydrogen sulfide
  • Measurement range (service range): Oxygen 0 ~ 25.0% (25.1~40.0%), Hydrogen sulfide 0-30.0ppm (30.5-150.0ppm)
  • 1 digit: (oxygen) 0.1vol% (hydrogen sulfide) 0.5ppm
  • Alarm settings: (oxygen) 1st 18.0%, 2nd 18.0%, OVER alarm 40.0% (hydrogen sulfide) 1st 10.0ppm, 2nd 10.0ppm, OVER alarm 150.0ppm
  • Detection principle: (oxygen/hydrogen sulfide) constant potential electrolytic type
  • Display: < Body >LCD Digital (Full Dots) < Detector >LCD Digital (7 segments +14 segments + Icon)
  • Indicators: Gas concentration indicator, clock indicator, battery level indicator, operating status indicator, temperature indicator
  • Display language: Japanese
  • Gas alarm display: Lamp flashes/Buzzer continuously modulated sound/Gas concentration display flashes at the time of gas alarm.
  • Gas alarm operation: self-holding
  • Failure alarm: System error/Sensor error/Battery voltage drop/Poor calibration
  • Failure Warning Display: Lamp Flashing/Buzzer Intermittent/Contents Display
  • Failure alarm operation: self-holding
  • Functions: Snapshot, Data Logger
  • Reel Part: Automatic Winding Type
  • Cable: 10 m (optional: extension cable up to 30 m)
  • Transmission Specifications: RS232C(External Electric Display * 1, PC Connection)/RS485 (Communication with Detector) * RC-2100 Communication Cable (optional) and Data Logger Management Program (optional) are required.
  • Power: 100 VAC or 2 AAA alkaline batteries
  • Continuous Use: Approximately 20 hours (New battery used, 25°C, no alarm, backlight always ON, manual lamp OFF)
  • Operating temperature range (°C): -20 to +50 (No sudden change)
  • Operating humidity range: 0~95%RH (no condensation)
  • Structure: < Body > Drip-Proof Structure JIS Drip-Proof Type 2 Equivalent < Detection Part > Dust-Proof Waterproof Structure IP67 Equivalent, Drop Durability 10 m
  • Explosion-Proof Structure: < Body > Non-Explosion-Proof (Detection Part) Non-Ignition Explosion-Proof Structure Ex nA IIB T4Gc (TIIS)
  • Certification: JIS T8201:2010 Oxygen Meter for Oxygen Deficiency Measurement Compliant/JIS T8205:2002 Hydrogen Sulfide Meter Compliant
  • External Dimensions (mm): < Main Unit > Approx. 275 (W) x 340 (H) x 180 (D) (Excluding Protrusion) < Detection Unit > Approx. 63 (W) x 97.8 (H) x 42.5 (D) (Excluding Protrusion, Excluding Protect Cover)
  • Mass (kg): about 4
  •  

Package size:360×510×410 mm 4 kg  [About Package size]

Order No. 63-7822-47
Model No. GX-2100
Standard price JPY: - USD: -
Excange rate 1USD= 159.53JPY
Valid price in Japan
Quantity 1unit
Stock in Japan
Supplier Stock

Product Variations (Different Sizes, Specifications, Optional Products, etc.)

Product image Order No. Name Model No. Quantity Standard price Valid price in Japan Stock
[Supplier Stock]
63-7822-44 (Domestic Sales only in Japan) Hazardous Gas Detector for Manhole/Pit Work GX-2100 Type A [Standard 4 Component Specification] GX-2100 GX-2100 1unit JPY: - USD: -

63-7822-45 (Domestic Sales only in Japan) Hazardous Gas Detector for Manhole/Pit Work GX-2100 Type A/B Standard 4 Component Specification [Bluetooth Compatible] GX-2100 GX-2100 1unit JPY: - USD: -

63-7822-46 (Domestic Sales only in Japan) Hazardous Gas Detector for Manhole/Pit Work GX-2100 Type E [Oxygen/Hydrogen Sulfide] GX-2100 GX-2100 1unit JPY: - USD: -

63-7822-47 (Domestic Sales only in Japan) Hazardous Gas Detector for Manhole/Pit Work GX-2100 Type EJ [Oxygen/Hydrogen Sulfide (JIS Adapted)] GX-2100 GX-2100 1unit JPY: - USD: -