61-9417-91 Gas Detector Tube PYROTEC Tube with Traceability System Diagram + Certificate Of Test 51H
Features
- * Please let us know the address on the certificate.
Spec
- Detecting tube name: 51H Pyrotube
- Number of measurements of 1 box: 5
- Expiration date (year): 3
- Measurement gas name: Freon11 (trichlorofluoromethane)
- Measurement range: 275 - 6600ppm
- Standard suction times (n): 1
- Measurement time (hr): -
- Special remarks: Conversion factor used, Detection instrument No.840 (9-070-03) only
- Measurement gas name: Freon112 (tetrachlorodifluoroethane)
- Measurement range: 125 - 3000ppm
- Standard suction times (n): 1
- Measurement time (hr): -
- Special remarks: Conversion factor used, Detection instrument No.840 (9-070-03) only
- Measurement gas name: Freon113 (trichlorotrifluoroethane)
- Measurement range: 250 - 6000ppm
- Standard suction times (n): 1
- Measurement time (hr): -
- Special remarks: N0.840
- Measurement gas name: Freon113a (trichlorotrifluoroethane)
- Measurement range: 200 - 4800ppm
- Standard suction times (n): 1
- Measurement time (hr): -
- Special remarks: Conversion factor used, Detection instrument No.840 (9-070-03) only
- Measurement gas name: Freon114 (dichlorotetrafluoroethane)
- Measurement range: 475 - 11400ppm
- Standard suction times (n): 1
- Measurement time (hr): -
- Special remarks: Conversion factor used, Detection instrument No.840 (9-070-03) only
- Measurement gas name: Freon12 (dichlorotetrafluoroethane)
- Measurement range: 325 - 7800ppm
- Standard suction times (n): 1
- Measurement time (hr): -
- Special remarks: Conversion factor used, Detection instrument No.840 (9-070-03) only
- Measurement gas name: Freon22 (chlorodifluoromethane)
- Measurement range: 1000 - 24000ppm
- Standard suction times (n): 1
- Measurement time (hr): -
- Special remarks: Conversion factor used, Detection instrument No.840 (9-070-03) only
- Measurement gas name: Halothane
- Measurement range: 800 - 6400ppm
- Standard suction times (n): 1
- Measurement time (hr): -
- Special remarks: Conversion factor used, Detection instrument No.840 (9-070-03) only
Package size:150×55×15 mm [About Package size]
| Order No. | 61-9417-91 | |
|---|---|---|
| Model No. | 51H | |
| Standard price |
JPY: 15,500
USD: 97.16
Excange rate 1USD= 159.53JPY
Valid price in Japan |
|
| Quantity | 1box | |
| Stock in Japan |
|
|
| Supplier Stock |
|
|
Product Variations (Different Sizes, Specifications, Optional Products, etc.)
| Product image | Order No. | Name | Model No. |
Attached certificate |
Measurement range |
Quantity | Standard price | Valid price in Japan | Stock [Supplier Stock] |
|
|---|---|---|---|---|---|---|---|---|---|---|
![]() |
61-9417-92 | Gas Detector Tube PYROTEC Tube with Calibration Certificate (With Certificate Of Test) 51H | 51H | Calibration certificate (with results document) | 275ppm - 6600ppm,125ppm - 3000ppm,250ppm - 6000ppm,200ppm - 4800ppm,475ppm - 11400ppm,325ppm - 7800ppm,1000ppm - 24000ppm | 1box | JPY: 15,500 | USD: 97.16 |
|
|
![]() |
61-9417-93 | Gas Detector Tube PYROTEC Tube Calibration Certificate (With Certificate Of Test) with Traceability System Diagram 51H | 51H | Calibration certificate (with results document),Traceability system | 275ppm - 6600ppm,125ppm - 3000ppm,250ppm - 6000ppm,200ppm - 4800ppm,475ppm - 11400ppm,325ppm - 7800ppm,1000ppm - 24000ppm | 1box | JPY: 20,500 | USD: 128.50 |
|
|
![]() |
61-9417-89 | Gas Detector Tube PYROTEC Tube with Certificate Of Test 51H | 51H | Test result report | 275ppm - 6600ppm,125ppm - 3000ppm,250ppm - 6000ppm,200ppm - 4800ppm,475ppm - 11400ppm,325ppm - 7800ppm,1000ppm - 24000ppm | 1box | JPY: 11,500 | USD: 72.09 |
|
|
![]() |
61-9417-91 | Gas Detector Tube PYROTEC Tube with Traceability System Diagram + Certificate Of Test 51H | 51H | Test result report,Traceability system | 275ppm - 6600ppm,125ppm - 3000ppm,250ppm - 6000ppm,200ppm - 4800ppm,475ppm - 11400ppm,325ppm - 7800ppm,1000ppm - 24000ppm | 1box | JPY: 15,500 | USD: 97.16 |
|
|
![]() |
61-9417-90 | Gas Detector Tube PYROTEC Tube with Traceability System Diagram 51H | 51H | Traceability system | 275ppm - 6600ppm,125ppm - 3000ppm,250ppm - 6000ppm,200ppm - 4800ppm,475ppm - 11400ppm,325ppm - 7800ppm,1000ppm - 24000ppm | 1box | JPY: 11,500 | USD: 72.09 |
|
|
![]() |
9-806-06 | Gas Detector Tube PYROTEC Tube 51H | 51H | 275ppm - 6600 ppm,125 ppm - 3000 ppm,250 ppm - 6000 ppm,200 ppm - 4800 ppm,475 ppm - 11400 ppm,325 ppm - 7800 ppm,1000 ppm - 24000 ppm | 1box | JPY: 3,500 | USD: 21.94 |
|