61-0163-75 [Out of stock]Eppendorf Xplorer ® plus 12 channels 4861 000.830
Features
- The Eppendorf Xplorer is an electric pipette. Single, 8 and 12 channel pipettes were designed to aspirate and dispense liquid volumes from 0.5 μL to 10 mL. In addition, it removes much of the risk of potential manual pipetting errors. Intuitive operating concepts and ergonomic design, supported by the Eppendorf PhysioCare Concept ®, set a new standard for ease, accuracy and reproducibility. You can set it to nine different languages: Chinese, Dutch, English, French, German, Italian, Japanese, Portuguese, and Spanish. The Xplorer pipette is the device of choice when you need precisely adjustable parameters, reproducible and accurate results. This allows fatigue-free pipetting and maintains full control of the pipetting procedure at all times.
- Intuitive work concept for quick and easy work
- Multi-function rocker switch
- Selection dial
- Innovative ejector button
- Ergonomic display angle
- Convenient operation
- Powerful battery
- Flexible charging concept
- Spring-type nose cone (other than 5 mL and 10 mL)
- Adjustable according to external conditions (Geographic elevation, high density liquid, etc.)
Spec
- capacity Range : 50 -1200 μL
- color coding: green
- capacity : 50 μL
- 50 Relative systematic error in μL 1 ) : ± 8.0%
- 50 Absolute systematic error on μL 1 ) : ± 4.0 μL
- 50 μL Relative Coincidence Error 1 ) : ± 1.2%
- 50 μL Absolute Coincidence Error 1 ) : ± 0.6 μL
- capacity : 120 μL
- 120 Relative systematic error in μL 1 ) : ± 6.0%
- 120 Absolute systematic error on μL 1 ) : ± 7.2 μL
- 120 μL Relative Coincidence Error 1 ) : ± 0.9%
- 120 μL Absolute Coincidence Error 1 ) : ± 1.08 μL
- capacity : 600 μL
- 600 Relative systematic error in μL 1 ) : ± 2.7%
- 600 Absolute systematic error on μL 1 ) : ± 16.2 μL
- 600 μL Relative Coincidence Error 1 ) : ± 0.4%
- 600 μL Absolute Coincidence Error 1 ) : ± 2.4 μL
- capacity : 1200 μL
- 1200 Relative systematic error in μL 1 ) : ± 1.2%
- 1200 Absolute systematic error on μL 1 ) : ± 14.2 μL
- 1200 μL Relative Coincidence Error 1 ) : ± 0.3%
- 1200 μL Absolute Coincidence Error 1 ) : ± 3.6 μL
- 1) chisel, EN ISO 8655 error data applies when using genuine Eppendorf chips. Technical specifications are subject to change. Information may be incorrect or missing.
- Electric dispensing Pipette
- multichannel
| Order No. | 61-0163-75 | |
|---|---|---|
| Model No. | 4861 000.830 | |
| Standard price |
JPY: 274,000
USD: 1,717.55
Excange rate 1USD= 159.53JPY
Valid price in Japan |
|
| Quantity | 1piece | |
|
|
||
| Stock in Japan | - | |
Product Variations (Different Sizes, Specifications, Optional Products, etc.)
| Product image | Order No. | Name | Model No. | Quantity | Standard price | Valid price in Japan | Stock [Supplier Stock] |
|
|---|---|---|---|---|---|---|---|---|
![]() |
61-0163-69 | Eppendorf Xplorer ® plus 12 channels 4861 000.775 | 4861 000.775 | 1piece | JPY: 274,000 | USD: 1,717.55 |
|
|
![]() |
61-0163-71 | Eppendorf Xplorer ® plus 12 channels 4861 000.791 | 4861 000.791 | 1piece | JPY: 274,000 | USD: 1,717.55 |
|
|
![]() |
61-0163-73 | Eppendorf Xplorer ® plus 12 channels 4861 000.813 | 4861 000.813 | 1piece | JPY: 274,000 | USD: 1,717.55 |
|
|
![]() |
61-0163-75 | [Out of stock]Eppendorf Xplorer ® plus 12 channels 4861 000.830 | 4861 000.830 | 1piece | JPY: 274,000 | USD: 1,717.55 |
-
|
![[Out of stock]Eppendorf Xplorer ® plus 12 channels 4861 000.830](https://aimg.as-1.co.jp/c/61/0163/75/61016362.jpg?v=03790be0f2ba82c1280907a7033cf49dabaaa7c1)
![[Out of stock]Eppendorf Xplorer ® plus 12 channels 4861 000.830](https://aimg.as-1.co.jp/c/61/0163/75/61016362a.jpg?v=03790be0f2ba82c1280907a7033cf49dabaaa7c1)