It is a float type flowmeter used for flow measurement and can be used for flow measurement and control in a wide range of fields such as analytical equipment, pollution monitoring equipment, reaction testing equipment, and medical equipment.
Designed and manufactured according to various conditions of fluid, flow rate, pressure and temperature.
There are 3 types, A-type, B-type and C-type, depending on the difference of external dimensions (scale length).
Spec
Type/Flowmeter Total Height: C Type/200 mm
Main Material: Shinchu
Additional mechanism: without valve
outlet pressure: specified pressure (0.1~0.5 MPa)
Connection Diameter: Rc1/4
Installation Method: Panel Back Mounting: M17 Nuts/Panel Back Mounting: M3 Screws
Applicable gas types: Air, N2, H2, He, O2, Ar (other types, please contact us separately)
Maximum flow rate: 50~700 mL/min, specified at 1.0~3.0 L/min (see flow rate symbol table)
Calibration Temperature: 20°C(We can make it according to the operating temperature, so please contact us.)
Voltage: 0.7 MPa (0.5 MPa for 10 L/min or more)
Scale accuracy: ±3%/F.S.
Gas Contact Part: Pyrex Glass, SUS304, Shinchu, Nitrile Rubber
Order No.
60-3356-45
Standard price
JPY: 49,700USD: 309.23
Excange rate 1USD= 160.72JPY Valid price in Japan
Quantity
1unit
在庫数
サプライヤ在庫
商品のバリエーション (サイズ違い・スペック違い・オプション品など)
商品イメージ
アズワン品番
商品名
型番
QuantityQuantityass="init">
60-3356-45 Float Type Flowmeter Type C, without Brass Valve, 1/4 inch Connection Pressure Specification 【AXEL GLOBAL】 アズワン
It is a float type flowmeter used for flow measurement and can be used for flow measurement and control in a wide range of fields such as analytical equipment, pollution monitoring equipment, reaction testing equipment, and medical equipment.
Designed and manufactured according to various conditions of fluid, flow rate, pressure and temperature.
There are 3 types, A-type, B-type and C-type, depending on the difference of external dimensions (scale length).
仕様
Type/Flowmeter Total Height: C Type/200 mm
Main Material: Shinchu
Additional mechanism: without valve
outlet pressure: specified pressure (0.1~0.5 MPa)
Connection Diameter: Rc1/4
Installation Method: Panel Back Mounting: M17 Nuts/Panel Back Mounting: M3 Screws
Applicable gas types: Air, N2, H2, He, O2, Ar (other types, please contact us separately)
Maximum flow rate: 50~700 mL/min, specified at 1.0~3.0 L/min (see flow rate symbol table)
Calibration Temperature: 20°C(We can make it according to the operating temperature, so please contact us.)
Voltage: 0.7 MPa (0.5 MPa for 10 L/min or more)
Scale accuracy: ±3%/F.S.
Gas Contact Part: Pyrex Glass, SUS304, Shinchu, Nitrile Rubber