3-3627-06 [Discontinued]Fluorescence X-Ray Analysis Device Epsilon1 (Residual Metal Catalyst Analysis Contained in The Chemical Substance) 943084800061
特徴
- Compact energy-dispersive X-ray fluorescence spectrometry (XRF) device with built-in PC.
- Allows non-destructive qualitative and quantitative analysis of elements.
- The Omnian software can analyze elements from Na to Am in the periodic table (optional).
- Calibration curves for various industries are installed, so they can be analyzed immediately after delivery.
- It requires no special gas or power supply and is extremely inexpensive to analyze.
仕様
- Model number: 943084800061
- Measurement target: Residual metal catalyst analysis contained in the chemical substance
- Analysis element: Pd (palladium), Pt (platinum), Rh (rhodium), Ru (ruthenium), Ir (iridium)
- Measuring chamber size: 150 x 120 x 100mm
- Rated output: Maximum 5W
- Detector: High resolution Si semiconductor (SDD)
- Power supply: AC99 - 240V 50/60Hz
- Size: 380 x 400 x 360mm
- Touch panel size: 10.4 inches
- Weight: 24kg
- Accessories: Japanese software, Calibration sample, Consumables starting kits 100 times, Omnian software (Only 943084800011, 943084800041 are standard, Others are option settings)
| アズワン品番 | 3-3627-06 | |
|---|---|---|
| 型番 | 943084800061 | |
| Standard price |
JPY: 5,835,000
USD: 36,601.43
Excange rate 1USD= 159.42JPY
Valid price in Japan |
|
| 入り数 | 1unit | |
|
|
||
| Stock in Japan | - | |
Product VariationsProduct Variations">
[Discontinued]Fluorescence X-Ray Analysis Device Epsilon1 (Residual Metal Catalyst Analysis Contained in The Chemical Substance) 943084800061 3-3627-06 【AXEL GLOBAL】 アズワン
Contact us
PANalytikal
3-3627-06 [Discontinued]Fluorescence X-Ray Analysis Device Epsilon1 (Residual Metal Catalyst Analysis Contained in The Chemical Substance) 943084800061
特徴
- Compact energy-dispersive X-ray fluorescence spectrometry (XRF) device with built-in PC.
- Allows non-destructive qualitative and quantitative analysis of elements.
- The Omnian software can analyze elements from Na to Am in the periodic table (optional).
- Calibration curves for various industries are installed, so they can be analyzed immediately after delivery.
- It requires no special gas or power supply and is extremely inexpensive to analyze.
仕様
- Model number: 943084800061
- Measurement target: Residual metal catalyst analysis contained in the chemical substance
- Analysis element: Pd (palladium), Pt (platinum), Rh (rhodium), Ru (ruthenium), Ir (iridium)
- Measuring chamber size: 150 x 120 x 100mm
- Rated output: Maximum 5W
- Detector: High resolution Si semiconductor (SDD)
- Power supply: AC99 - 240V 50/60Hz
- Size: 380 x 400 x 360mm
- Touch panel size: 10.4 inches
- Weight: 24kg
- Accessories: Japanese software, Calibration sample, Consumables starting kits 100 times, Omnian software (Only 943084800011, 943084800041 are standard, Others are option settings)
-
アズワン品番
3-3627-06
型番
943084800061
標準価格
JPY: 5,835,000
USD: 36,601.43
Excange rate 1USD= 159.42JPY
Valid price in Japan
入り数
1unit
在庫数
-
商品のバリエーション (サイズ違い・スペック違い・オプション品など)
Product imageASONEs="init">
[Discontinued]Fluorescence X-Ray Analysis Device Epsilon1 (Residual Metal Catalyst Analysis Contained in The Chemical Substance) 943084800061 3-3627-06 【AXEL GLOBAL】 アズワン
Contact us
PANalytikal
3-3627-06 [Discontinued]Fluorescence X-Ray Analysis Device Epsilon1 (Residual Metal Catalyst Analysis Contained in The Chemical Substance) 943084800061
Features
- Compact energy-dispersive X-ray fluorescence spectrometry (XRF) device with built-in PC.
- Allows non-destructive qualitative and quantitative analysis of elements.
- The Omnian software can analyze elements from Na to Am in the periodic table (optional).
- Calibration curves for various industries are installed, so they can be analyzed immediately after delivery.
- It requires no special gas or power supply and is extremely inexpensive to analyze.
Spec
- Model number: 943084800061
- Measurement target: Residual metal catalyst analysis contained in the chemical substance
- Analysis element: Pd (palladium), Pt (platinum), Rh (rhodium), Ru (ruthenium), Ir (iridium)
- Measuring chamber size: 150 x 120 x 100mm
- Rated output: Maximum 5W
- Detector: High resolution Si semiconductor (SDD)
- Power supply: AC99 - 240V 50/60Hz
- Size: 380 x 400 x 360mm
- Touch panel size: 10.4 inches
- Weight: 24kg
- Accessories: Japanese software, Calibration sample, Consumables starting kits 100 times, Omnian software (Only 943084800011, 943084800041 are standard, Others are option settings)
-
Order No.
3-3627-06
Model No.
943084800061
Standard price
JPY: 5,835,000
USD: 36,601.43
Excange rate 1USD= 159.42JPY
Valid price in Japan
Quantity
1unit
Stock in Japan
-
Product Variations (Different Sizes, Specifications, Optional Products, etc.)
Product image
Order No.
Name
Model No.
Quantity
Standard price
Valid price in Japan
Stock
[Supplier Stock]

3-3627-01
[Discontinued]Fluorescence X-Ray Analysis Device Epsilon1 (Academia Package Of Research, Education Organization, Etc.) 943084800011
943084800011
1unit
JPY: 5,025,000
USD: 31,520.51
-

3-3627-02
[Discontinued]Fluorescence X-Ray Analysis Device Epsilon1 (S Analysis in Fuel Oil (Gasoline, Diesel Fuel, Kerosene, Etc.)) 943084800021
943084800021
1unit
JPY: 4,730,000
USD: 29,670.05
-

3-3627-03
[Discontinued]Fluorescence X-Ray Analysis Device Epsilon1 (Additive Agent Element Analysis Contained in Lubricating Oil) 943084800031
943084800031
1unit
JPY: 5,140,000
USD: 32,241.88
-

3-3627-04
[Discontinued]Fluorescence X-Ray Analysis Device Epsilon1 (Mineral, Resource Analysis) 943084800041
943084800041
1unit
JPY: 5,523,000
USD: 34,644.34
-

3-3627-05
[Discontinued]Fluorescence X-Ray Analysis Device Epsilon1 (Mineral Analysis in Milk Powder) 943084800051
943084800051
1unit
JPY: 5,140,000
USD: 32,241.88
-

3-3627-06
[Discontinued]Fluorescence X-Ray Analysis Device Epsilon1 (Residual Metal Catalyst Analysis Contained in The Chemical Substance) 943084800061
943084800061
1unit
JPY: 5,835,000
USD: 36,601.43
-
Product Catalog
Catalog Name
Page
SANIFOODS Pamphlet 2020
85
SANIFOODS Catalog 2016 [Inspection and Sanitation]
237
3-3627-06 [Discontinued]Fluorescence X-Ray Analysis Device Epsilon1 (Residual Metal Catalyst Analysis Contained in The Chemical Substance) 943084800061
特徴
- Compact energy-dispersive X-ray fluorescence spectrometry (XRF) device with built-in PC.
- Allows non-destructive qualitative and quantitative analysis of elements.
- The Omnian software can analyze elements from Na to Am in the periodic table (optional).
- Calibration curves for various industries are installed, so they can be analyzed immediately after delivery.
- It requires no special gas or power supply and is extremely inexpensive to analyze.
仕様
- Model number: 943084800061
- Measurement target: Residual metal catalyst analysis contained in the chemical substance
- Analysis element: Pd (palladium), Pt (platinum), Rh (rhodium), Ru (ruthenium), Ir (iridium)
- Measuring chamber size: 150 x 120 x 100mm
- Rated output: Maximum 5W
- Detector: High resolution Si semiconductor (SDD)
- Power supply: AC99 - 240V 50/60Hz
- Size: 380 x 400 x 360mm
- Touch panel size: 10.4 inches
- Weight: 24kg
- Accessories: Japanese software, Calibration sample, Consumables starting kits 100 times, Omnian software (Only 943084800011, 943084800041 are standard, Others are option settings)
| アズワン品番 | 3-3627-06 | |
|---|---|---|
| 型番 | 943084800061 | |
| 標準価格 |
JPY: 5,835,000
USD: 36,601.43
Excange rate 1USD= 159.42JPY
Valid price in Japan |
|
| 入り数 | 1unit | |
|
|
||
| 在庫数 | - | |
商品のバリエーション (サイズ違い・スペック違い・オプション品など)
Product imageASONEs="init">
3-3627-06 [Discontinued]Fluorescence X-Ray Analysis Device Epsilon1 (Residual Metal Catalyst Analysis Contained in The Chemical Substance) 943084800061Features
Spec
Product Variations (Different Sizes, Specifications, Optional Products, etc.)
Product Catalog
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![[Discontinued]Fluorescence X-Ray Analysis Device Epsilon1 (Residual Metal Catalyst Analysis Contained in The Chemical Substance) 943084800061](https://aimg.as-1.co.jp/c/3/3627/06/03362701.jpg?v=03790be0f2ba82c1280907a7033cf49dabaaa7c1)