Contact usFind by keyword"init"> 1-7793-16 Memory meter ®(With JCSS calibration certificate) SK-L754 【AXEL GLOBAL】<!--@[ss-27]@--> アズワン<!--@/[ss-27]@-->

AS ONE AS ONE

取扱点数300万点
How to use
Cách sử dụng
Contact us
すべてのカテゴリ
Contact us
Quote Other Requests
  • AXEL GLOBAL
  • カテゴリ一覧
  • Lab Instruments & Supplies
  • Measuring Instruments
  • Temperature, Humidity
  • Data Logger
  • Memory meter ®(With JCSS calibration certificate) 等
  • 1-7793-16 Memory meter ®(With JCSS calibration certificate) SK-L754
Sato Keiryoki Mfg. Co., Ltd.

1-7793-16 Memory meter ®(With JCSS calibration certificate) SK-L754

  • Print
  • PDF
他のバリエーション
  • Memory meter ®(With JCSS calibration certificate) SK-L754
  • Memory meter ®(With JCSS calibration certificate) SK-L754
  • Memory meter ®(With JCSS calibration certificate) SK-L754
  • Memory meter ®(With JCSS calibration certificate) SK-L754
  • Memory meter ®(With JCSS calibration certificate) SK-L754
  • Memory meter ®(With JCSS calibration certificate) SK-L754
  • Figures
    FiguresFiguresass="init"> 1-7793-16 Memory meter ®(With JCSS calibration certificate) SK-L754 【AXEL GLOBAL】<!--@[ss-27]@--> アズワン<!--@/[ss-27]@-->

    AS ONE AS ONE

    取扱点数300万点
    How to use
    Cách sử dụng
    Contact us
    すべてのカテゴリ
    Contact us
    Quote Other Requests
    • AXEL GLOBAL
    • カテゴリ一覧
    • Lab Instruments & Supplies
    • Measuring Instruments
    • Temperature, Humidity
    • Data Logger
    • Memory meter ®(With JCSS calibration certificate) 等
    • 1-7793-16 Memory meter ®(With JCSS calibration certificate) SK-L754
    Sato Keiryoki Mfg. Co., Ltd.

    1-7793-16 Memory meter ®(With JCSS calibration certificate) SK-L754

    • 印刷
    • PDF
    他のバリエーション
    • Memory meter ®(With JCSS calibration certificate) SK-L754
    • Memory meter ®(With JCSS calibration certificate) SK-L754
    • Memory meter ®(With JCSS calibration certificate) SK-L754
    • Memory meter ®(With JCSS calibration certificate) SK-L754
    • Memory meter ®(With JCSS calibration certificate) SK-L754
    • Memory meter ®(With JCSS calibration certificate) SK-L754
    • <!--@[pd-1]@-->図面・資料<!--@/[pd-1]@-->
      図面・資料

    Features

    • This product is a set of "JCSS proofreading" documents that are valid internationally through international MRA.
    • # Calibration points: Temperature 10,23,40 degrees C/Humidity 30,60,90% This is a "temperature and humidity" data logger that can store up to 16,000 measurement data.
    • The memory interval of 1 second is approximately 4 hours, and the memory interval of 90 minutes is approximately 2 years and 9 months.
    • How to calculate total storage time from storage interval and storage capacity: storage capacity x storage interval = total storage time # # Example: 16000 x 5 seconds =22.2 hours # You can choose from 14 storage intervals.
    • * Data can be stored at various intervals: 1 second, 2 seconds, 5 seconds, 10 seconds, 15 seconds, 30 seconds, 1 minute, 2 minutes, 5 minutes, 10 minutes, 15 minutes, 30 minutes, 60 minutes and 90 minutes.
    • Memory appointments are available.
    • If you reserve (set) a date and time to start memory, memory will automatically start at the reserved date and time.
    • A separate sensor SK-L754-2 is included.
    • You can choose from the following four storage methods according to your intended use.
    • 1. One-time method: This method keeps storing data until the memory is full. Memory is automatically terminated when the number of stored data reaches 16000.
    • 2. Endless method (Overwrite mode) When the memory is full, data is overwritten from the beginning. It is the best method for collecting data for the last fixed period.
    • 3. Data number specification method: You can specify the number of data items to be stored in advance between 1~16000. It is the best method when you do not want to take unnecessary data.
    • 4. Page system (Memory split mode): The memory can be divided into 4 parts (4 pages). Each device sequentially stores data from different locations and times, allowing multiple devices to be used with one device. 1 page can store 4000 data.
    • Analysis software is included as standard * * Standard graph processing, real-time monitoring and other stored data can be fully utilized. It can also be saved in CSV format, so you can use commercially available spreadsheet software.
    • Key-lock function prevents misoperation during memory.
    • Upper and lower alarm values can be set (When the alarm is activated, the LED lights and the "Hi/Lo" mark on the LCD flashes.)
    • Either battery or AC adapter (sold separately) can be used.
    • The AC adapter has priority when used in combination. When the power supply from the AC adapter stops due to a power failure, etc., the battery automatically switches to the battery.
    • The stored measurement data is stored in the internal memory even if the power is turned off.
    • The stored measurement data can be downloaded to a PC or copied to a microSD memory card (sold separately). (It can be copied while it is being stored.)
    • A six-digit ID number can be assigned to the device. If you use more than one unit, you can easily identify the equipment.
    • - Analysis Software Features
    • ★ Up to 10 indicators can be connected simultaneously using a USB hub.
    • ★ Graph display, storage, printing and analysis according to usage (Expansion, reduction, period selection, integrated temperature analysis function, etc.).
    • ★ Data can be analyzed with commercially available spreadsheet software when saved in CSV format.
    • ★ real-time monitoring. During real-time monitoring, alarm settings can be set and alert emails can be sent to pre-registered email addresses.
    • Compatible OS: Windows10/8.1/8 (all 64bit/32bit Japanese versions).
    • Memory: 4GB or more (32bit)8GB or more (64bit) Hard disk: 4GB or more of free space required Other: USB port, CD-ROM drive required Internet connection and email address required to use mail alert function

    Spec

    • measurement range: Temperature/-20.0 to 80.0 ° C, Humidity/5.0 to 95.0% rh
    • resolution : Temperature 0.1 ° C/Humidity 0.1%
    • Measurement accuracy:
    • Temperature ± 0.7 ° C (0 to 40 ° C), ± 0.8 ° C (Other)
    • Humidity ± 3.2% rh (at 15 to 40 ° C, 5 to 90% rh)/± 5.2% rh (at 0 to 15 ° C, 5 to 95% rh)/± 5.3% rh (at 40 to 60 ° C, 5 to 95% rh)/± 6.3% rh (Other)
    • Display Function: Temperature/Humidity Warning (ALM)
    • storage system
    • Status Display (REC/RES)
    • Memory (bar.)
    • SD Memory
    • low battery mark
    • key lock mark
    • each error message
    • Setting value display at each setting
    • Number of measurement channels: 1 temperature channel, 1 humidity channel
    • Storage capacity: Each channel 16000 data
    • Memory interval: 1 sec., 2 sec., 5 sec., 10 sec., 15 sec., 30 sec., 1 min., 2 min., 5 min., 10 min., 15 min., 30 min., 60 min., 14/90 Street
    • External memory: up to microSD, SDHC/32 GB.
    • ※ Please use pre-formatted memory. The format supported by the tester is FAT 32 format. NTFS is not supported.
    • Body environment used Condition: -10 to 60 ° C 85% rh or less (No condensation)
    • power supply : AA size alkaline battery 2 pieces or dedicated AC adapter (Options)
    • battery Life : In Measurement Mode/Approximately 500 Hours , In Memory Mode/Each interval Can Store 16,000 Data (When LCD is off)
    • It is recommended to use the AC adapter when the LCD is always displayed or in measurement mode.
    • Dimensions:
    • Body/(W) 114 x (H) 80 x (D) 35 mm (Excluding Projections)
    • Sensor Part/φ 11 x L 34 mm
    • Connector Part/φ 12 x L 40 mm
    • Cord/About 1.6 m
    • material : Sensor Unit/PC Plastic , Connector Unit/PVC Plastic , Cord/PVC Plastic
    • Weight: Main Unit: about 227 g, Sensor: about 35 g
    • Accessories:
    • JCSS Calibration Results/calibration certificate 2-Piece Set
    • Detachable sensor SK-L 754 -2 (sensor filter)
    • AA size type alkaline battery 2 pieces
    • Communication Cable (1.5 m) 1 piece
    • one instruction manual
    • One copy of Quick Manual
    • Analysis Software CD-ROM 1 piece
    • Optional Product: No. 8229 -50 Dedicated AC Adapter (Cable 1.5 m)
    •  

    Package size:240×335×70 mm 590 g  [About Package size]

    Order No. 1-7793-16
    Model No. SK-L754
    JAN Code 4974425950072
    Standard price JPY: 140,600 USD: 881.34
    Excange rate 1USD= 159.53JPY
    Valid price in Japan
    Quantity 1piece
    Stock in Japan
    Supplier Stock

    商品のバリエーション (サイズ違い・スペック違い・オプション品など)

    商品イメージ アズワン品番 商品名 型番 入り数 標準価格 標準価格(ドル) アズワン在庫
    [サプライヤ在庫]
    1-7793-15 Memory meter ®(With JCSS calibration certificate) SK-L751 SK-L751 1piece JPY: 76,800 USD: 481.41

    1-7793-16 Memory meter ®(With JCSS calibration certificate) SK-L754 SK-L754 1piece JPY: 140,600 USD: 881.34

    関連商品

    1 / 1 ページ

    Memory meter ® SK-L754

    Memory meter ® SK-L754

    掲載カタログ情報

    掲載カタログ名 掲載ページ
    AS ONE Catalog 2025 [Instruments for Laboratory] 539
    AS ONE Catalog 2023 [Instruments for Laboratory] 636
    AS ONE Catalog 2021 [Instruments for Laboratory] 597

    [$1]Memory meter ®(With JCSS calibration certificate)[/$1]

    Explore AXEL

    • Categories
    • Catalogs
    • Brands

    How to use

    • User's Guide
    • For Re-seller
    • For End-User

    Get to Know Us

    • About us
    • Site Policy
    • Privacy Policy
    • Cookies Policy

    Let Us Help You

    • Contact Us
    • Product proposal
      (for Supplier)
    • Other requests

    Countries and Regions

    • English

    • China

    • Indonesia

    • Korea

    • Thailand

    • Vietnam

    AS ONE Group

    • AXEL-SHOP (Japan)

    • AS ONE INTERNATIONAL

    • AS ONE 亚速旺上海商贸 (China)

    Copyright © AS ONE Corporation. All rights reserved.