[PR Electronics]Automation & Control Gear
Filters
-
PR Electronics 4116, Current Output, Signal Conditioner 4116
4116 Type - Universal Transmitter. 4116 Universal Transmitters are for linearizing electronic temperature measurement with RTD or TC sensor. Also for the conversion of linear resistance variation to a standard analog current/voltage signal, i.e. from solenoids and butterfly valves or linear movements with attached potentiometer. The transmitter are programmable via detachable display front (4501), process calibration, signal and relay simulation, password protection, error diagnostics and selection of help text in several languages. The 4116 is designed according to strict safety requirements and is therefore suitable for application in SIL 2 installations. Input for RTD, TC, Ohm, potentiometer, mA and V Power supply and signal isolator for 2-wire transmitters Output for current, voltage and 2 relays Universal AC or DC supply A green/red front LED indicates normal operation and malfunction. A yellow LED is ON for each active output relay 4-port 2.3 kVAC galvanic isolation FM-approved for installation in Div. 2 DIN Rail mounting Please order the Display Front separately (stock-no. ; 796-6890 796-6890 )
1 products found
JPY: 75,600
USD: 473.89
-
PR Electronics 4114, Current Output, Signal Conditioner 4114
4114 Type - Universal Transmitter. 4114 Universal Transmitters are for linearizing electronic temperature measurement with RTD or TC sensor. Also for the conversion of linear resistance variation to a standard analog current/voltage signal, i.e. from solenoids and butterfly valves or linear movements with attached potentiometer. The transmitter are programmable via detachable display front (4501), process calibration, signal simulation, password protection, error diagnostics and selection of help text in several languages. The 4114 is designed according to strict safety requirements and is therefore suitable for application in SIL 2 installations. Input for RTD, TC, Ohm, potentiometer, mA and V Power supply and signal isolator for 2-wire transmitters Output for current and voltage Universal AC or DC supply A green/red front LED indicates normal operation and malfunction 4-port 2.3 kVAC galvanic isolation FM-approved for installation in Div. 2 DIN Rail mounting Please order the Display Front separately (stock-no. ; 796-6890 796-6890 )
1 products found
JPY: 64,400
USD: 403.69
-
PR Electronics 5714D , LED Digital Panel Multi-Function Meter for Current, Potentiometer Signals, Resistance, 5714D
5700 Series - Programmable LED Indicators. Range of 5700 series Multi-functional Panel Meters are characterized by their flexibility and stability. The panel meters meet nearly every demand for display readout of process signals, and have universal input and supply capabilities. They provide a real-time measurement of your process value no matter the industry, and are engineered to provide a user-friendly, reliable relay of information, even in demanding environment The 5700 series are easily configured via PC, DIP switches or using built in push buttons on the front of the unit making deployment fast and simple. 4-digit 14-segment LED display Front key programmable, all standard operational parameters can be adjusted of the front function keys Help texts in eight languages available Display is easily scaled to the correct process value (from -9999 to 9999) Input for mA, V, Ohm, RTD, TC and potentiometer Relay output 5715 series: 4 x SPDT Relay output 5714A series: Standard Display Relay output 5714B series: 2 relays Relay output 5714C series: Analogue Output Relay output 5714D series: Analogue Output and 2 relays Analog output 0-20mA IP65 protection on the front For extra protection in extreme environments a splash-proof cover is available (stock-no.: ; 796-7010 796-7010 )
1 products found
JPY: 93,400
USD: 585.47
-
Temperature Transmitter, 7.2 → 35 V dc 5331A3B
5300 Series - In-Head Temperature Transmitter. 5300 series of temperature transmitters for converting industrial process temperature signals to analog. 2-wire programmable transmitter High measurement accuracy For DIN form B sensor head mounting Programming with Loop Link 5909 communications interface (stock-no.: ; 796-7020 796-7020 )
1 products found
JPY: 68,500
USD: 429.39
-
PR Electronics 5714A , LED Digital Panel Multi-Function Meter for Current, Potentiometer Signals, Resistance, 5714A
5700 Series - Programmable LED Indicators. Range of 5700 series Multi-functional Panel Meters are characterized by their flexibility and stability. The panel meters meet nearly every demand for display readout of process signals, and have universal input and supply capabilities. They provide a real-time measurement of your process value no matter the industry, and are engineered to provide a user-friendly, reliable relay of information, even in demanding environment The 5700 series are easily configured via PC, DIP switches or using built in push buttons on the front of the unit making deployment fast and simple. 4-digit 14-segment LED display Front key programmable, all standard operational parameters can be adjusted of the front function keys Help texts in eight languages available Display is easily scaled to the correct process value (from -9999 to 9999) Input for mA, V, Ohm, RTD, TC and potentiometer Relay output 5715 series: 4 x SPDT Relay output 5714A series: Standard Display Relay output 5714B series: 2 relays Relay output 5714C series: Analogue Output Relay output 5714D series: Analogue Output and 2 relays Analog output 0-20mA IP65 protection on the front For extra protection in extreme environments a splash-proof cover is available (stock-no.: ; 796-7010 796-7010 )
1 products found
JPY: 65,500
USD: 410.58
-
PR Electronics 5715B , LED Digital Panel Multi-Function Meter for Current, Potentiometer Signals, Resistance, 5715B
5700 Series - Programmable LED Indicators. Range of 5700 series Multi-functional Panel Meters are characterized by their flexibility and stability. The panel meters meet nearly every demand for display readout of process signals, and have universal input and supply capabilities. They provide a real-time measurement of your process value no matter the industry, and are engineered to provide a user-friendly, reliable relay of information, even in demanding environment The 5700 series are easily configured via PC, DIP switches or using built in push buttons on the front of the unit making deployment fast and simple. 4-digit 14-segment LED display Front key programmable, all standard operational parameters can be adjusted of the front function keys Help texts in eight languages available Display is easily scaled to the correct process value (from -9999 to 9999) Input for mA, V, Ohm, RTD, TC and potentiometer Relay output 5715 series: 4 x SPDT Relay output 5714A series: Standard Display Relay output 5714B series: 2 relays Relay output 5714C series: Analogue Output Relay output 5714D series: Analogue Output and 2 relays Analog output 0-20mA IP65 protection on the front For extra protection in extreme environments a splash-proof cover is available (stock-no.: ; 796-7010 796-7010 )
1 products found
JPY: 97,400
USD: 610.54
-
Temperature Control Software for use with 5114, 5115, 5116, 5131, 5223, 5225, 5331, 5333, 5334, 5335, 5337, 5343, 5715, 5909
5909 Type - Loop Link for USB. Loop Link 5909 consists of a communication box with USB cable to the PC, necessary cables for connection to the devices, a CD-ROM with the configuration program PReset and an installation manual. The communication box is supplied from the USB port to the PC. Loop Link 5909 is used for the configuration of: 5114, 5115, 5116, 5131, 5331, 5333, 5334, 5335, 5337, 5343, 5715, 6331, 6333, 6334, 6335 and 6337
1 products found
JPY: 68,100
USD: 426.88
-
1, 2 Channel Isolation Barrier With Analogue Output, 250 V ac max 9116B1
9116B Type - Ex Universal Converter. The 9116B is an universal converter with 1-channel. The device is for converting and scaling of temperature, voltage, potentiometer and linear resistance signals. 1-channel universal converter Input for RTD, TC, Ohm, potentiometer, mA and V Reduced Uo Ex data ; 8.3 V for active input signals Active / passive mA output and relay output Configuration and monitoring by way of detachable display front (PR 4501); process calibration and signal simulation Copying of the configuration from one device to others of the same type via the display front Please order the Display Front PR4501 separately (stock-no. ; 796-6890 796-6890 ) Advanced relay configuration, e.g. setpoint, window, delay, sensor error indication and power monitoring Power supply and signal isolator for 2-wire transmitters Can be mounted in the safe area and in zone 2 / cl. 1 div. 2 and receive signals from zone 0, 1, 2 and zone 20, 21, 22 including M1 / Class I/II/III, Div. 1, Gr. A-G SIL 2-certified via Full Assessment. Designed, developed and certified for use in SIL 2 applications according to the requirements of IEC 61508 Front LED indicates operation status, malfunction and relay status 2.6 kVac galvanic isolation between input, output and supply Can be supplied separately or installed on power rail, PR type 9400 DIN rail mounting
1 products found
JPY: 137,000
USD: 858.77
-
PR Electronics ATEX, 3103, Current Output, Signal Conditioner 3103
3100 Type - Isolated Repeater. 3103 and 3108 type are for isolation and conversion of standard current signals. Suitable for galvanic separation of analog current signals and elimination of ground loops and measurement of floating signals. Repeater for 0-20mA Response time ; 7 ms Splitter function: 1 in - 2 out (only 3108 type, stock-no. ; 796-7082 796-7082 ) Simple, no setup needed Input is protected against overvoltage and polarity error Inputs and outputs are floating and galvanically separated Installation in ATEX Ex zone 2 / IECEx Zone 2 / FM division 2 Suitable for environments with high vibration stress, e.g. ships Slimline housing of 6 mm
1 products found
JPY: 47,500
USD: 297.75
-
PR Electronics ATEX, 3108, Current Output, Signal Conditioner 3108
3100 Type - Isolated Repeater. 3103 and 3108 type are for isolation and conversion of standard current signals. Suitable for galvanic separation of analog current signals and elimination of ground loops and measurement of floating signals. Repeater for 0-20mA Response time ; 7 ms Splitter function: 1 in - 2 out (only 3108 type, stock-no. ; 796-7082 796-7082 ) Simple, no setup needed Input is protected against overvoltage and polarity error Inputs and outputs are floating and galvanically separated Installation in ATEX Ex zone 2 / IECEx Zone 2 / FM division 2 Suitable for environments with high vibration stress, e.g. ships Slimline housing of 6 mm
1 products found
JPY: 58,000
USD: 363.57
-
PR Electronics ATEX, 3109, Current Output, Signal Conditioner 3109
3100 Type - Isolated Converter. 3104, 3109 and 3114 type are for isolation and conversion of standard DC signals. Suitable for galvanic separation of analog DC signals and elimination of ground loops and measurement of floating signals. Conversion of standard DC signals Slimline housing of 6 mm Power supply and signal isolator for 2-wire transmitter Loop supply >17 V DIP-switch configured Inputs and outputs are floating and galvanically separated Isolation 2.5 mm² Installation in ATEX Ex zone 2 / IECEx zone 2 / FM division 2
1 products found
JPY: 65,100
USD: 408.07
-
PR Electronics ATEX, 3105, Current Output, Signal Conditioner 3105
3105 Type - Isolated Converter. 3105 type is for isolation and conversion of standard DC signals. Suitable for galvanic separation of analog DC signals and elimination of ground loops and measurement of floating signals. Conversion of standard DC signals Slimline housing of 6 mm DIP-switch configured Input is protected against overvoltage and polarity error Inputs and outputs are floating and galvanically separated Suitable for environments with high vibration stress, e.g. ships
1 products found
JPY: 46,500
USD: 291.48
-
PR Electronics ATEX, 3114, Current Output, Signal Conditioner 3114
3100 Type - Isolated Converter. 3104, 3109 and 3114 type are for isolation and conversion of standard DC signals. Suitable for galvanic separation of analog DC signals and elimination of ground loops and measurement of floating signals. Conversion of standard DC signals Slimline housing of 6 mm Power supply and signal isolator for 2-wire transmitter Loop supply >17 V DIP-switch configured Inputs and outputs are floating and galvanically separated Isolation 2.5 mm² Installation in ATEX Ex zone 2 / IECEx zone 2 / FM division 2
1 products found
JPY: 65,500
USD: 410.58
-
PR Electronics ATEX, 3185, Voltage Output, Signal Conditioner 3185A1
3100 Type - Loop Powered Isolator. 3185 type is a 1 or 2 channel input loop powered isolator. Inputs and outputs are floating and galvanically separated. The converter eliminates ground loops and can be used for measuring floating signals. Also provides surge suppression and protects control systems from transients and noise. Signal 1:1 functional range 0-23 mA 1-channel version, stock-no. ; 796-7102 796-7102 2-channel version, stock-no. ; 796-7105 796-7105 Low input voltage drop, typ 1.35 V + Vout Powered by the analog input current signal loop The output is voltage limited to 17.5 Vdc Excellent conversion accuracy, better than 0.1% in the range 0-20.5 mA High galvanic isolation of 2.5 kVac Fast response time ; 5 ms Excellent signal/noise ratio > 60 dB Can be mounted in Safe area or in Zone 2 and Cl. 1 Div 2. area Slimline 6 mm housing DIN rail mounting
1 products found
JPY: 34,600
USD: 216.89
-
Lin.R, NI100, PT100 Temperature Transmitter, 8 → 30 V dc, -40 → +85 °C 5333D
5300 Series - In-Head Temperature Transmitter. 5300 series of temperature transmitters for converting industrial process temperature signals to analog. 2-wire programmable transmitter High measurement accuracy For DIN form B sensor head mounting Programming with Loop Link 5909 communications interface (stock-no.: ; 796-7020 796-7020 )
1 products found
JPY: 40,700
USD: 255.12
-
PR Electronics 3186, Current Output, Signal Conditioner 3186A2
3100 Type - 2-wire Transmitter Isolator. 3186 type is a 1 or 2 channel input loop powered isolator. Inputs and outputs are floating and galvanically separated. The converter eliminates ground loops and can be used for measuring floating signals. 1:1 output loop powered isolator of 2-wire transmitter Excellent accuracy 1-channel versions, stock-no. ; 796-7109 796-7109 ; ; 136-8709 136-8709 2-channel version, stock-no. ; 796-7118 796-7118 ; ; 136-8710 136-8710 Signal 1:1 functional range 3.5-23 mA Low input to output voltage drop typ. 2.5 V Fast response time ; 5 ms Excellent signal/noise ratio > 60 dB Powered by the host loop voltage Wide supply range from 6-35 V High galvanic isolation of 2.5 kVac Can be mounted in Safe area or in Zone 2 and Cl. 1 Div 2. area Slimline 6 mm housing DIN rail mounting
1 products found
JPY: 58,300
USD: 365.45
-
Linear Resistance, RTD, TC, Voltage Temperature Transmitter, 7.2 → 30 V dc 6331B2B
6331B 2-Wire Programmable Transmitter. 2-wire programmable transmitter can be programmed to measure temperatures within all ranges defined by the standards and has a high measurement accuracy. Features and Benefits. RTD, TC, Ohm or mV input Galvanic isolation Can be installed in Ex zone 0 1 ( ; 136-8669 136-8669 ) or 2 ( ; 136-8670 136-8670 ) channel versions available DIN Rail mounting (vertically or horizontally) RTD and resistance inputs have cable compensation for 2, 3 and 4-wire connection A limit can be programmed on the output signal Continuous check of vital stored data for safety reasons Linearised temperature measurement with PT100..PT1000, Ni1000…Ni1000 or TC sensor Conversion of linear resistance variation to a standard analogue current signal, for instance from valves or Ohmic level sensors Amplification of a bipolar mV signal to a standard 4…20 mA current signal
1 products found
JPY: 152,000
USD: 952.80
-
TC, Voltage Temperature Transmitter, 7.2 → 30 V dc 6334A2A
6334A 2-Wire Programmable Transmitter. 2-wire programmable transmitter can be programmed to measure temperatures within all TC ranges defined by the standards and has a high measurement accuracy. Features and Benefits. TC Input Galvanic Isolation Programmable sensor error value 1 ( ; 136-8671 136-8671 ) or 2 ( ; 136-8675 136-8675 ) channel options available DIN Rail mounting (vertically or horizontally) Cold junction compensation (CJC) with a built-in temperature sensor A limit can be programmed on the output signal Continuous check of vital stored data for safety reasons Linearised temperature measurement with TC sensor Amplification of bipolar mV signals to a 4…20 mA signal, optionally linearised according to a defined linearisation function
1 products found
JPY: 57,600
USD: 361.06
-
Linear Resistance, RTD Temperature Transmitter, 8 → 30 V dc 6333B1A
6333B 2-Wire Programmable Transmitter. 2-wire programmable transmitter can be programmed to measure temperatures within all RTD ranges defined by the standards and has a high measurement accuracy. Features and Benefits. RTD or Ohm input Three wire connection Can be installed in Ex zone 0 1 ( ; 136-8673 136-8673 ) or 2 ( ; 136-8674 136-8674 ) channel options available DIN Rail mounting (vertically or horizontally) The RTD and resistance inputs have cable compensation for three wire connection A limit can be programmed on the output signal Linearised temperature measurement with PT 100…PT1000 or Ni100…Ni1000 sensor Conversion of linear resistance variation to a standard analogue current signal, for instance from valves or Ohmic level sensors
1 products found
JPY: 53,000
USD: 332.23
-
Linear Resistance, RTD Temperature Transmitter, 8 → 30 V dc 6333B1B
6333B 2-Wire Programmable Transmitter. 2-wire programmable transmitter can be programmed to measure temperatures within all RTD ranges defined by the standards and has a high measurement accuracy. Features and Benefits. RTD or Ohm input Three wire connection Can be installed in Ex zone 0 1 ( ; 136-8673 136-8673 ) or 2 ( ; 136-8674 136-8674 ) channel options available DIN Rail mounting (vertically or horizontally) The RTD and resistance inputs have cable compensation for three wire connection A limit can be programmed on the output signal Linearised temperature measurement with PT 100…PT1000 or Ni100…Ni1000 sensor Conversion of linear resistance variation to a standard analogue current signal, for instance from valves or Ohmic level sensors
1 products found
JPY: 81,000
USD: 507.74
-
TC, Voltage Temperature Transmitter, 7.2 → 30 V dc 6334A2B
6334A 2-Wire Programmable Transmitter. 2-wire programmable transmitter can be programmed to measure temperatures within all TC ranges defined by the standards and has a high measurement accuracy. Features and Benefits. TC Input Galvanic Isolation Programmable sensor error value 1 ( ; 136-8671 136-8671 ) or 2 ( ; 136-8675 136-8675 ) channel options available DIN Rail mounting (vertically or horizontally) Cold junction compensation (CJC) with a built-in temperature sensor A limit can be programmed on the output signal Continuous check of vital stored data for safety reasons Linearised temperature measurement with TC sensor Amplification of bipolar mV signals to a 4…20 mA signal, optionally linearised according to a defined linearisation function
1 products found
JPY: 99,700
USD: 624.96
-
TC Temperature Transmitter, 7.2 → 30 V dc 6334B2B
6334B 2-Wire Programmable Transmitter. 2-wire programmable transmitter can be programmed to measure temperatures within all TC ranges defined by the standards and has a high measurement accuracy. Features and Benefits. TC Input Galvanic Isolation Programmable sensor error value 1 ( ; 136-8677 136-8677 ) or 2 ( ; 136-8676 136-8676 ) channel options available DIN Rail mounting (vertically or horizontally) Cold junction compensation (CJC) with a built-in temperature sensor A limit can be programmed on the output signal Continuous check of vital stored data for safety reasons Linearised temperature measurement with TC sensor Amplification of bipolar mV signals to a 4…20 mA signal, optionally linearised according to a defined linearisation function
1 products found
JPY: 115,000
USD: 720.87
-
TC Temperature Transmitter, 7.2 → 30 V dc 6334B2A
6334B 2-Wire Programmable Transmitter. 2-wire programmable transmitter can be programmed to measure temperatures within all TC ranges defined by the standards and has a high measurement accuracy. Features and Benefits. TC Input Galvanic Isolation Programmable sensor error value 1 ( ; 136-8677 136-8677 ) or 2 ( ; 136-8676 136-8676 ) channel options available DIN Rail mounting (vertically or horizontally) Cold junction compensation (CJC) with a built-in temperature sensor A limit can be programmed on the output signal Continuous check of vital stored data for safety reasons Linearised temperature measurement with TC sensor Amplification of bipolar mV signals to a 4…20 mA signal, optionally linearised according to a defined linearisation function
1 products found
JPY: 68,100
USD: 426.88
-
Linear Resistance, RTD, TC, Voltage Temperature Transmitter, 8 → 30 V dc 6335D2A
6335D 2-Wire HART Transmitter. 2-wire HART 5 protocol transmitter can be programmed to measure temperatures within all ranges defined by the standards and has a high measurement accuracy. Features and Benefits. RTD, TC, Ohm or mV input HART 5 protocol Can be installed in Ex zone 0 1 ( ; 136-8678 136-8678 ) or 2 ( ; 136-8679 136-8679 ) channel versions available DIN Rail mounting (vertically or horizontally) The RTD and resistance inputs have cable compensation for 2, 3 and 4-wire connection Designed according to strict safety requirements and is therefore suitable for application in SIL 2 installations Continuous check of vital stored data for safety reasons Sensor error detection according to the guidelines in NAMUR NE89 Linearised temperature measurement with PT100…PT1000, Ni100…Ni1000 or TC sensor Difference or average temperature measurement of 2 resistance or TC sensors Conversion of linear resistance from valves or Ohmic level sensors Amplification of a bipolar mV signal to a standard 4…20 mA current signal Connection of up to 15 channels to a digital 2-wire signal with HART communication
1 products found
JPY: 141,000
USD: 883.85
-
Linear Resistance, RTD, TC, Voltage Temperature Transmitter, 8 → 30 V dc 6335D2B
6335D 2-Wire HART Transmitter. 2-wire HART 5 protocol transmitter can be programmed to measure temperatures within all ranges defined by the standards and has a high measurement accuracy. Features and Benefits. RTD, TC, Ohm or mV input HART 5 protocol Can be installed in Ex zone 0 1 ( ; 136-8678 136-8678 ) or 2 ( ; 136-8679 136-8679 ) channel versions available DIN Rail mounting (vertically or horizontally) The RTD and resistance inputs have cable compensation for 2, 3 and 4-wire connection Designed according to strict safety requirements and is therefore suitable for application in SIL 2 installations Continuous check of vital stored data for safety reasons Sensor error detection according to the guidelines in NAMUR NE89 Linearised temperature measurement with PT100…PT1000, Ni100…Ni1000 or TC sensor Difference or average temperature measurement of 2 resistance or TC sensors Conversion of linear resistance from valves or Ohmic level sensors Amplification of a bipolar mV signal to a standard 4…20 mA current signal Connection of up to 15 channels to a digital 2-wire signal with HART communication
1 products found
JPY: 250,000
USD: 1,567.10
-
Various Thermocouple Input Temperature Transmitter, 8 → 30 V dc 6337D2A
6337D 2-Wire HART Transmitter. 2-wire HART transmitter is designed according to strict safety requirements and is suitable for applications in SIL installations. Features and Benefits. 2 Analogue inputs and 5 device selectable variables with status available HART protocol revision selectable from HART 5 or HART 7 1 ( ; 136-8680 136-8680 ) or 2 ( ; 136-8681 136-8681 ) channel converter for RTD, TC, Ohm and bipolar mV signals Continuous check of vital stored data Linearised temperature measurement with TC and RTD sensors HART communication and 4…20 mA analogue PV output for individual, difference or average temperature measurement of up to two RTD or TC input sensors Conversation of linear resistance to a standard analogue current signal Amplification of bipolar mV signals to standard 4…20 mA current signals Up to 63 transmitters (HART 7) can be connected in a multi-drop communication setup DIN Rail mounting in hazardous gas and dust areas Meets NAMUR NE 21, NE43 and NE89 recommendations and ensures top measurements performance in harsh EMC environments
1 products found
JPY: 155,000
USD: 971.60
-
Various Thermocouple Input Temperature Transmitter, 8 → 30 V dc 6337D2B
6337D 2-Wire HART Transmitter. 2-wire HART transmitter is designed according to strict safety requirements and is suitable for applications in SIL installations. Features and Benefits. 2 Analogue inputs and 5 device selectable variables with status available HART protocol revision selectable from HART 5 or HART 7 1 ( ; 136-8680 136-8680 ) or 2 ( ; 136-8681 136-8681 ) channel converter for RTD, TC, Ohm and bipolar mV signals Continuous check of vital stored data Linearised temperature measurement with TC and RTD sensors HART communication and 4…20 mA analogue PV output for individual, difference or average temperature measurement of up to two RTD or TC input sensors Conversation of linear resistance to a standard analogue current signal Amplification of bipolar mV signals to standard 4…20 mA current signals Up to 63 transmitters (HART 7) can be connected in a multi-drop communication setup DIN Rail mounting in hazardous gas and dust areas Meets NAMUR NE 21, NE43 and NE89 recommendations and ensures top measurements performance in harsh EMC environments
1 products found
JPY: 276,000
USD: 1,730.08
-
Various Thermocouple Input Temperature Transmitter, 8 → 30 V dc 6337A2A
6337A 2-Wire HART Transmitter. 2-wire HART transmitter is designed according to strict safety requirements and is suitable for applications in SIL installations. Features and Benefits. 2 Analogue inputs and 5 device selectable variables with status available HART protocol revision selectable from HART 5 or HART 7 1 ( ; 136-8682 136-8682 ) or 2 ( ; 136-8683 136-8683 ) channel converter for RTD, TC, Ohm and bipolar mV signals Continuous check of vital stored data Linearised temperature measurement with TC and RTD sensors HART communication and 4…20 mA analogue PV output for individual, difference or average temperature measurement of up to two RTD or TC input sensors Conversation of linear resistance to a standard analogue current signal Amplification of bipolar mV signals to standard 4…20 mA current signals Up to 63 transmitters (HART 7) can be connected in a multi-drop communication setup DIN Rail mounting in Safe Area or Zone 2/22 Meets NAMUR NE 21, NE43 and NE89 recommendations and ensures top measurements performance in harsh EMC environments
1 products found
JPY: 129,000
USD: 808.63
-
Various Thermocouple Input Temperature Transmitter, 8 → 30 V dc 6337A2B
6337A 2-Wire HART Transmitter. 2-wire HART transmitter is designed according to strict safety requirements and is suitable for applications in SIL installations. Features and Benefits. 2 Analogue inputs and 5 device selectable variables with status available HART protocol revision selectable from HART 5 or HART 7 1 ( ; 136-8682 136-8682 ) or 2 ( ; 136-8683 136-8683 ) channel converter for RTD, TC, Ohm and bipolar mV signals Continuous check of vital stored data Linearised temperature measurement with TC and RTD sensors HART communication and 4…20 mA analogue PV output for individual, difference or average temperature measurement of up to two RTD or TC input sensors Conversation of linear resistance to a standard analogue current signal Amplification of bipolar mV signals to standard 4…20 mA current signals Up to 63 transmitters (HART 7) can be connected in a multi-drop communication setup DIN Rail mounting in Safe Area or Zone 2/22 Meets NAMUR NE 21, NE43 and NE89 recommendations and ensures top measurements performance in harsh EMC environments
1 products found
JPY: 230,000
USD: 1,441.74
-
PR Electronics 5223, Current, Relay, Voltage Output, Frequency / Current Converter 5223A1
5223A Programmable f/l-f/f Converter. 5223A Programmable converter has an f/l function that performs frequency to current and voltage conversion and an f/f function for pulse division or multiplication. The f/f function also works as a buffer, collecting fast pulse trains. Pulse calculator Frequency generator (used as a time base or clock generator) Galvanic isolation 5 front LEDs to indicate f1 and f2 active inputs, dig.out 1 and 2 active outputs and a programmable error signal Analogue current and voltage output Analogue current output can be configured to any current within 0…20 mA range Voltage output range is selectable between 0…10 V dc and 0…1 V dc by internal jumpers PNP/NPN output, optional relays Universal supply A scale factor may be entered in all functions, using either digital inputs, pulse addition or subtraction Input and supply polarity reversal protection Can be configured with a standard PC and the Loop Link communications unit or delivered fully configured
1 products found
JPY: 177,000
USD: 1,109.51
-
RTD Temperature Transmitter, 8 → 35 V dc 2914
2914 2-Wire Room Temperature Transmitter. 2914 2-wire transmitter that measures room temperature is built in a slim cabinet design. A precision PT100 sensor with small mass is mounted on the transmitter input, therefore achieving a fast response time. Features and Benefits. 2-wire Output signal of 4…20 mA Easy mounting Protected against polarity reversal Bottom of cabinet can be attached to a wall by two screws Visible or hidden cable access Measures temperature in offices, heating plants, factories, living rooms and similar dry rooms Suitable as a transmitter for controllers, trip amplifiers, displays or superior SCADA systems
1 products found
JPY: 63,600
USD: 398.67
-
1 Channel Galvanic Isolator With Converter, 300 V ac max, 35mA max 3186B1
3100 Type - 2-wire Transmitter Isolator. 3186 type is a 1 or 2 channel input loop powered isolator. Inputs and outputs are floating and galvanically separated. The converter eliminates ground loops and can be used for measuring floating signals. 1:1 output loop powered isolator of 2-wire transmitter Excellent accuracy 1-channel versions, stock-no. ; 796-7109 796-7109 ; ; 136-8709 136-8709 2-channel version, stock-no. ; 796-7118 796-7118 ; ; 136-8710 136-8710 Signal 1:1 functional range 3.5-23 mA Low input to output voltage drop typ. 2.5 V Fast response time ; 5 ms Excellent signal/noise ratio > 60 dB Powered by the host loop voltage Wide supply range from 6-35 V High galvanic isolation of 2.5 kVac Can be mounted in Safe area or in Zone 2 and Cl. 1 Div 2. area Slimline 6 mm housing DIN rail mounting
1 products found
JPY: 40,400
USD: 253.24
-
2 Channel Galvanic Isolator With Converter, 300 V ac max, 35mA max 3186B2
3100 Type - 2-wire Transmitter Isolator. 3186 type is a 1 or 2 channel input loop powered isolator. Inputs and outputs are floating and galvanically separated. The converter eliminates ground loops and can be used for measuring floating signals. 1:1 output loop powered isolator of 2-wire transmitter Excellent accuracy 1-channel versions, stock-no. ; 796-7109 796-7109 ; ; 136-8709 136-8709 2-channel version, stock-no. ; 796-7118 796-7118 ; ; 136-8710 136-8710 Signal 1:1 functional range 3.5-23 mA Low input to output voltage drop typ. 2.5 V Fast response time ; 5 ms Excellent signal/noise ratio > 60 dB Powered by the host loop voltage Wide supply range from 6-35 V High galvanic isolation of 2.5 kVac Can be mounted in Safe area or in Zone 2 and Cl. 1 Div 2. area Slimline 6 mm housing DIN rail mounting
1 products found
JPY: 58,300
USD: 365.45
-
PR Electronics 4104, Active Bipolar, Active Unipolar, Current, Passive 2-Wire, Voltage Output, Signal Conditioner 4104
4104 Universal Uni-/Bipolar Signal Transmitter. 4104 Universal uni-/bipolar signal transmitter used to measure and output uni-/bipolar voltage and current signals. It works with both passive and active inputs and outputs which makes it perfect for power matching current loops. Features and Benefits. Uses 4501 ( ; 796-6890 796-6890 ) display for programming and process monitoring Fast ; 20 ms response time for measuring signals produced by torque, position, current and acceleration sensors Excellent ; 0.05% accuracy Use configurable bipolar or unipolar I/O Excitation source enables measurement of two or three wire transmitters Selectable direct or inverse I/O makes it suitable for proportional control applications Meets NAMUR NE21 and NE43 recommendation, ensuring high accuracy in harsh EMC environments and easy sensor error detection Each unit is tested to a high 2.3 kV ac, 3-port galvanic isolation level Excellent signal to noise ratio of >60 dB All programming can be password protected Lower power consumption for side by side mounting Approved for marine applications
1 products found
JPY: 57,100
USD: 357.93
-
PR Electronics Current, Voltage Output, Universal Transmitter 4179
1 products found
JPY: 66,800
USD: 418.73
-
PR Electronics 4184, Current, Voltage Output, Universal Transmitter 4184
1 products found
JPY: 67,700
USD: 424.37
-
PR Electronics 5116A, Current Output, Signal Conditioner 5116A
5116A Type - Programmable Transmitter. 5116A programmable transmitter are for linearizing electronic temperature measurement. Also for the conversion of linear resistance variation e.g, from solenoids and butterfly valves or linear movements with attached potentiometer. Input for RTD, TC, mV, Ohm, potentiometer, mA and V 2-wire supply ; 16.5 V Bipolar voltage input Input can be calibrated to the exact span of the process Zero drift on the process signal can be adjusted by a single press of the front buttton Output for current, voltage and 2 relays Green front LED indicates normal operation and malfunction Yellow LED is ON for each active output relay Continuous check of vital stored data for safety reasons 3-port 3.75 kVAC galvanic isolation Universal supply by AC or DC Power supply and signal isolator for 2-wire transmitters
1 products found
JPY: 142,000
USD: 890.12
-
Temperature Transmitter, 7.5 → 35 V dc 5131AB
5131A - 2-wire Programmable Transmitter. The 5131A is a 2-wire programmable transmitter. The transmitter is for conversion of linear resistance variation to a standard analog current / voltage signal, for example from solenoids and butterfly valves or linear movements with attached potentiometer. This transmitter can be configured with the software program PReset using a standard PC and the Loop Link communications unit (stock-no. ; 796-7020 796-7020 ). 2-wire programmable transmitter 1-channel, stock-no. ; 827-5491 827-5491 2-channel, stock-no. ; 796-6893 796-6893 Input for RTD, TC, mV, linear resistance, mA, and V sample Linearized, electronic temperature measurement with RTD or TC sensor 4- or 3-wire connection automatic cable compensation or 2-wire connection with programmable cable compensation Current input programmable in range 0-100 mA and voltage inputs in range 0-250 Vdc 4-20 mA loop output, can be configured to any current within 0-20 mA range Voltage output range is selectable between 0-10 Vdc Independent channel jumper selectable inputs for current/voltage or temperature Programming can be performed with or without a power supply 3.75 kVac galvanic isolation between the channels Configurable sensor error detection including NAMUR NE43 DIN rail mounting
1 products found
JPY: 158,000
USD: 990.41
-
Temperature Transmitter, 19.2 → 300 V dc, 21.6 → 253 V ac 5114AA
5114A Type - Programmable Transmitter. 5114A programmable transmitter are for linearizing electronic temperature measurement. Also for the conversion of linear resistance variation e.g, from solenoids and butterfly valves or linear movements with attached potentiometer. The 5114A transmitter can be configured, with or without a power supply, using the PReset software and the Loop Link communications unit. Input for RTD, TC, mV, linear resistance, mA and V Automatic 4- / 3-wire or programmable 2-wire cable compensation Active or passive current output and selectable voltage output 1-channel version (stock-no. ; 796-6904 796-6904 ) 2-channel version (stock-no. ; 796-6929 796-6929 ) Jumper selectable Universal voltage supply 17.1 Vdc loop and 2.5 Vdc potentiometer supplies 3-port 3.75 kVac galvanic isolation Configurable sensor error detection including NAMUR NE43 Separation of circuits in PELV/SELV installations
1 products found
JPY: 123,000
USD: 771.02
-
PR Electronics 5114A, Current Output, Signal Conditioner 5114AB
5114A Type - Programmable Transmitter. 5114A programmable transmitter are for linearizing electronic temperature measurement. Also for the conversion of linear resistance variation e.g, from solenoids and butterfly valves or linear movements with attached potentiometer. The 5114A transmitter can be configured, with or without a power supply, using the PReset software and the Loop Link communications unit. Input for RTD, TC, mV, linear resistance, mA and V Automatic 4- / 3-wire or programmable 2-wire cable compensation Active or passive current output and selectable voltage output 1-channel version (stock-no. ; 796-6904 796-6904 ) 2-channel version (stock-no. ; 796-6929 796-6929 ) Jumper selectable Universal voltage supply 17.1 Vdc loop and 2.5 Vdc potentiometer supplies 3-port 3.75 kVac galvanic isolation Configurable sensor error detection including NAMUR NE43 Separation of circuits in PELV/SELV installations
1 products found
JPY: 212,000
USD: 1,328.90