AS ONE AS ONE

Listed products : 3 milion products
How to use
Cách sử dụng
Contact us
All Categories
[Discontinued]Heatstroke Wet Bulb Globe Temperature Meter SK-150GT 61-0067-84 【AXEL GLOBAL】<!--@[ss-27]@--> アズワン<!--@/[ss-27]@-->

AS ONE AS ONE

取扱点数300万点
How to use
Cách sử dụng
Contact us
すべてのカテゴリ
Contact us
Quote Other Requests
  • AXEL GLOBAL
  • カテゴリ一覧
  • Lab Instruments & Supplies
  • Measuring Instruments
  • Environmental Measurement
  • Heatstroke Meter
  • 61-0067-84 [Discontinued]Heatstroke Wet Bulb Globe Temperature Meter SK-150GT
Sato Keiryoki Mfg. Co., Ltd.

61-0067-84 [Discontinued]Heatstroke Wet Bulb Globe Temperature Meter SK-150GT

  • Print
  • PDF
  • [Discontinued]Heatstroke Wet Bulb Globe Temperature Meter SK-150GT
  • [Discontinued]Heatstroke Wet Bulb Globe Temperature Meter SK-150GT
  • [Discontinued]Heatstroke Wet Bulb Globe Temperature Meter SK-150GT
  • [Discontinued]Heatstroke Wet Bulb Globe Temperature Meter SK-150GT
  • Products Information
  • Instruction Manual
    取扱説明書

Features

  • JIS B 7922 Class 2 compliant.
  • Handy type WBGT index measuring instrument with integrated black bulb thermometer, thermometer and hygrometer.
  • You can measure the WBGT index, which is used as a guideline for preventing heatstroke and as an evaluation of heat stress in the working environment.
  • For physical education and club activities in schools
  • For indoor and outdoor sports such as sporting events
  • For work sites in hot environments or construction work
  • For road construction and track maintenance
  • For agricultural work
  • With alarm warning: A buzzer will let you know when the setting value (any WBGT index) is reached
  • With hard case: Convenient for carrying and storage
  • With standard seal: The standard seal is based on the WBGT index for preventing heatstroke. Select one of three types depending on the use, and attach it to the main body.
  • * The WBGT index is calculated differently depending on the measurement environment.

SpecSpec class="init"> [Discontinued]Heatstroke Wet Bulb Globe Temperature Meter SK-150GT 61-0067-84 【AXEL GLOBAL】<!--@[ss-27]@--> アズワン<!--@/[ss-27]@-->

AS ONE AS ONE

取扱点数300万点
How to use
Cách sử dụng
Contact us
すべてのカテゴリ
Contact us
Quote Other Requests
  • AXEL GLOBAL
  • カテゴリ一覧
  • Lab Instruments & Supplies
  • Measuring Instruments
  • Environmental Measurement
  • Heatstroke Meter
  • 61-0067-84 [Discontinued]Heatstroke Wet Bulb Globe Temperature Meter SK-150GT
Sato Keiryoki Mfg. Co., Ltd.

61-0067-84 [Discontinued]Heatstroke Wet Bulb Globe Temperature Meter SK-150GT

  • 印刷
  • PDF
  • [Discontinued]Heatstroke Wet Bulb Globe Temperature Meter SK-150GT
  • [Discontinued]Heatstroke Wet Bulb Globe Temperature Meter SK-150GT
  • [Discontinued]Heatstroke Wet Bulb Globe Temperature Meter SK-150GT
  • [Discontinued]Heatstroke Wet Bulb Globe Temperature Meter SK-150GT
  • メーカー商品情報
  • <!--@[pr-4]@-->取扱説明書<!--@/[pr-4]@-->
    取扱説明書

特徴

  • JIS B 7922 Class 2 compliant.
  • Handy type WBGT index measuring instrument with integrated black bulb thermometer, thermometer and hygrometer.
  • You can measure the WBGT index, which is used as a guideline for preventing heatstroke and as an evaluation of heat stress in the working environment.
  • For physical education and club activities in schools
  • For indoor and outdoor sports such as sporting events
  • For work sites in hot environments or construction work
  • For road construction and track maintenance
  • For agricultural work
  • With alarm warning: A buzzer will let you know when the setting value (any WBGT index) is reached
  • With hard case: Convenient for carrying and storage
  • With standard seal: The standard seal is based on the WBGT index for preventing heatstroke. Select one of three types depending on the use, and attach it to the main body.
  • * The WBGT index is calculated differently depending on the measurement environment.

仕様

  • Prior to measurement, Please set measurement environment.
  • Room measure (IN): Sun does not reach in a room or outdoor
  • WBGT index (℃) = 0.7 x humidity sphere temperature (℃) + 0.3 x black sphere temperature (℃)
  • Outdoor measurement (OUT): Outdoor where the sun reaches
  • WBGT index (℃) = 0.7 x humidity sphere temperature (℃) + 0.2 x black sphere temperature + 0.1 x dry sphere temperature (℃)] *in heatstroke under high temperature environment, Is the general term for failure contracting a disease collapsed balance of moisture and salt (sodium such as) within the body and heat regulation function to collapse. In the worst case, Variable might result in death, If you know the preventive methods it can be prevented.
  • With HOlD function
  • With high value (mAx)/minimum value (mIN) display function
  • With auto power OFF function
  • With screw hole can be fixed to camera tripod
  • Measurement environment setting function with WBGT index
  • WBGT index alarm: Settings range 20.0 - 49.9℃ the buzzer warning (release disabled)
  • Battery life: Continuous use about 600 hour (alarm operation none) *WBGT index: Acronym for WetBulbGlobeTempeRatuRe (wet sphere black sphere temperature), Index that is used to evaluate the thermal stress of workers (hot environment) defined in ISO7243/JISZ8504. Wet-bulb temperature, Black sphere temperature (radiant heat), Is one of the volume feeling temperature calculated from dry Sphere temperature. *WBGT index: Acronym for WetBulbGlobeTempeRatuRe (wet sphere black sphere temperature), Index that is used to evaluate the thermal stress of workers (hot environment) defined in ISO7243/JISZ8504. Wet-bulb temperature, Black sphere temperature (radiant heat), Is one of the volume feeling temperature calculated from dry Sphere temperature.
  • Measurement range: Temperature: 0.0 - 50.0℃, Black sphere temperature: 0.0 - 80.0℃, WBGT index: 0.0 - 50.0℃, Humidity: 10.0 - 95.0%Rh
  • Accuracy: Temperature (TA) ±0.6℃, Black sphere temperature (TG) ±2℃, WBGT index ±2℃, Humidity (RH) ±3%Rh (20 - 90% Rh at between 20℃ - 30℃) ±5%Rh (other than the left)
  • Body dimensions: (W) 71 x (H) 275 x (D) 30mm, Black sphere dimensions: φ60mm
  • Weight: Approximately 240g (including dry cell)
  •  

Package sizePackage sizes="init"> [Discontinued]Heatstroke Wet Bulb Globe Temperature Meter SK-150GT 61-0067-84 【AXEL GLOBAL】<!--@[ss-27]@--> アズワン<!--@/[ss-27]@-->

AS ONE AS ONE

取扱点数300万点
How to use
Cách sử dụng
Contact us
すべてのカテゴリ
Contact us
Quote Other Requests
  • AXEL GLOBAL
  • カテゴリ一覧
  • Lab Instruments & Supplies
  • Measuring Instruments
  • Environmental Measurement
  • Heatstroke Meter
  • 61-0067-84 [Discontinued]Heatstroke Wet Bulb Globe Temperature Meter SK-150GT
Sato Keiryoki Mfg. Co., Ltd.

61-0067-84 [Discontinued]Heatstroke Wet Bulb Globe Temperature Meter SK-150GT

  • 印刷
  • PDF
  • [Discontinued]Heatstroke Wet Bulb Globe Temperature Meter SK-150GT
  • [Discontinued]Heatstroke Wet Bulb Globe Temperature Meter SK-150GT
  • [Discontinued]Heatstroke Wet Bulb Globe Temperature Meter SK-150GT
  • [Discontinued]Heatstroke Wet Bulb Globe Temperature Meter SK-150GT
  • メーカー商品情報
  • <!--@[pr-4]@-->取扱説明書<!--@/[pr-4]@-->
    取扱説明書

特徴

  • JIS B 7922 Class 2 compliant.
  • Handy type WBGT index measuring instrument with integrated black bulb thermometer, thermometer and hygrometer.
  • You can measure the WBGT index, which is used as a guideline for preventing heatstroke and as an evaluation of heat stress in the working environment.
  • For physical education and club activities in schools
  • For indoor and outdoor sports such as sporting events
  • For work sites in hot environments or construction work
  • For road construction and track maintenance
  • For agricultural work
  • With alarm warning: A buzzer will let you know when the setting value (any WBGT index) is reached
  • With hard case: Convenient for carrying and storage
  • With standard seal: The standard seal is based on the WBGT index for preventing heatstroke. Select one of three types depending on the use, and attach it to the main body.
  • * The WBGT index is calculated differently depending on the measurement environment.

仕様

  • Prior to measurement, Please set measurement environment.
  • Room measure (IN): Sun does not reach in a room or outdoor
  • WBGT index (℃) = 0.7 x humidity sphere temperature (℃) + 0.3 x black sphere temperature (℃)
  • Outdoor measurement (OUT): Outdoor where the sun reaches
  • WBGT index (℃) = 0.7 x humidity sphere temperature (℃) + 0.2 x black sphere temperature + 0.1 x dry sphere temperature (℃)] *in heatstroke under high temperature environment, Is the general term for failure contracting a disease collapsed balance of moisture and salt (sodium such as) within the body and heat regulation function to collapse. In the worst case, Variable might result in death, If you know the preventive methods it can be prevented.
  • With HOlD function
  • With high value (mAx)/minimum value (mIN) display function
  • With auto power OFF function
  • With screw hole can be fixed to camera tripod
  • Measurement environment setting function with WBGT index
  • WBGT index alarm: Settings range 20.0 - 49.9℃ the buzzer warning (release disabled)
  • Battery life: Continuous use about 600 hour (alarm operation none) *WBGT index: Acronym for WetBulbGlobeTempeRatuRe (wet sphere black sphere temperature), Index that is used to evaluate the thermal stress of workers (hot environment) defined in ISO7243/JISZ8504. Wet-bulb temperature, Black sphere temperature (radiant heat), Is one of the volume feeling temperature calculated from dry Sphere temperature. *WBGT index: Acronym for WetBulbGlobeTempeRatuRe (wet sphere black sphere temperature), Index that is used to evaluate the thermal stress of workers (hot environment) defined in ISO7243/JISZ8504. Wet-bulb temperature, Black sphere temperature (radiant heat), Is one of the volume feeling temperature calculated from dry Sphere temperature.
  • Measurement range: Temperature: 0.0 - 50.0℃, Black sphere temperature: 0.0 - 80.0℃, WBGT index: 0.0 - 50.0℃, Humidity: 10.0 - 95.0%Rh
  • Accuracy: Temperature (TA) ±0.6℃, Black sphere temperature (TG) ±2℃, WBGT index ±2℃, Humidity (RH) ±3%Rh (20 - 90% Rh at between 20℃ - 30℃) ±5%Rh (other than the left)
  • Body dimensions: (W) 71 x (H) 275 x (D) 30mm, Black sphere dimensions: φ60mm
  • Weight: Approximately 240g (including dry cell)
  •  

Package size:350×220×75 mm 980 g  [About Package size]

Order No. 61-0067-84
型番 SK-150GT
JANコード 4974425831005
標準価格 JPY: 28,000 USD: 175.64
Excange rate 1USD= 159.42JPY
Valid price in Japan
入り数 1piece
  <!--@[ia-1]@-->取扱停止<!--@/[ia-1]@-->
在庫数 -

[$1][Discontinued]Heatstroke Wet Bulb Globe Temperature Meter[/$1]

Explore AXEL

  • Categories
  • Catalogs
  • Brands

How to use

  • User's Guide
  • For Re-seller
  • For End-User

Get to Know Us

  • About us
  • Site Policy
  • Privacy Policy
  • Cookies Policy

Let Us Help You

  • Contact Us
  • Product proposal
    (for Supplier)
  • Other requests

Countries and Regions

  • English

  • China

  • Indonesia

  • Korea

  • Thailand

  • Vietnam

AS ONE Group

  • AXEL-SHOP (Japan)

  • AS ONE INTERNATIONAL

  • AS ONE 亚速旺上海商贸 (China)

Copyright © AS ONE Corporation. All rights reserved.