60-6794-67 Pressure Reducing Valve (GD-41-43) 0.05Mpa GD-41A25A0.05Mpa
Spec
- Applicable fluids: Cold/Hot Water [Steam for cleaning and sterilization (Maximum temperature 130°C, continuous ventilation within 30 minutes)]
- Primary Pressure: 0.07~2.0 MPa (0.2 MPa or Less for Cleaning/Sterilization Steam)
- Secondary Pressure: A/0.02-0.1 MPa
- Min. differential pressure: 0.05 MPa
- Maximum pressure reduction ratio: 10:1 for cold/hot water, 20:1 for air/carbon dioxide/nitrogen gas
- Fluid temperature: 5~90°C(In the case of steam for cleaning and sterilization, the maximum temperature should be 130°C, and after the steam has been vented, allow at least 4 hours for re-venting the steam.)
- Connection: JIS Rc
- Set pressure: 0.05Mpa
| Order No. | 60-6794-67 | |
|---|---|---|
| Model No. | GD-41A25A0.05Mpa | |
| Standard price |
JPY: 123,000
USD: 771.55
Excange rate 1USD= 159.42JPY
Valid price in Japan |
|
| Quantity | 1piece | |
| Stock in Japan |
|
|
| Supplier Stock |
|
|