3-6823-01 [Discontinued]12 CH Data Logger, Main Unit, Temperature, Voltage and Humidity Measurement 167 x 91 x 35.8mm ADL12
Features
- This data multi-logger is capable of thermocouple or voltage measurement on up to 12-channels. (Humidity measurement is only possible on 1-channel at +5V and with 12-channels port.)
- By connecting logger to PC with USB cable, possible to create measuring graphs and lists. (You need to download application from specified URL and install it to your PC.)
- Recorded data is saved in CSV format either to SD card or to your PC.
- Possible to move recorded data to PC with USB cable.(This operation cannot be performed while data is being recorded.)
- Since logger is charged via USB, possible to either use accompanying AC adapter, or any USB port or portable battery to charge it.
Spec
- Model number: ADL12
- Maximum external dimensions (mm): 167 x 91 x 35.8
- measurement item: Temperature, Voltage and Humidity
- Thermo-thermocouple measurements: B, R, S, N, K, E, J, T (Select one)
- measurement temperature range: 200 to 1370 °C (When using K class thermocouple)
- Voltage measurement: 100, 500 mV, 1.5, 10, 50 V
- Measure measurement: ±0.05% of rdg + 1.0 °C (K: 100 to 1370 °C at 25 °C)
- Voltage measurement accuracy: ±0.1% of F.S.
- Humidity Measurement: 0 to 100 %RH
- Input channel: Analog/12 CH for humidity measurement + 5V-OUT/1CH
- Input terminal shape: Screw terminal M3/* 1 M3.5 (Outside dimensions 6.2mm or less/inner diameter 3.2mm or higher)
- Voltage measurement: 100, 500 V, 15, 50, 10, 50
- Voltage measurement accuracy: ±0.1% of F.S.
- Humidity Measurement: 0 to 100 %RH
- Humidity measurement accuracy: ±5 %RH (TYP) (10 to 95 %RH at 23 °C)
- Input channel: Analog/12 CH for humidity measurement + 5V-OUT/1CH
- Input terminal shape: Screw terminal M3/* 3.5 (Outside 6mm or less/inner diameter 3.2mm or higher)
- Sampling period: 5 seconds, 10 seconds, 30 seconds, 60 seconds, 5 minutes, 10 minutes, 30 minutes, 60 minutes
- PCI/F: USB 2.0 (full speed) mini B type
- Card slots: 1 slot, no SDHC, approx. 512 MB/approx. 1 GB/2 GB
- Memory: PC storage using SD card applications
- recording format: saving from CSV recording start to 1 file
- Number of records: 5 million (2 GB)
- Accessories: Simplified manual, AC adapter and USB cable approx. 1M (For power supply and communication)
- * There is no attached wire material on the body. Prepare for your application.
- * We have a demo machine.
- * Supported OS: Windows (R) 7/8/8.1/10
- * Function: Real-time measurement on an application, start/end of recording, data saving, body configuration, SD card data reading, display
- * Display method: Graph display (Cascade feature), list display, maximum, minimum, average, and comparison values for measurement data
- a> Download Dedicated Applications (v 110)
- * Supported OS: Windows ® 7/8/8.1/10 (32 64 bit)
- If you need a driver for USB connections , a>
Package size:195×130×60 mm 420 g [About Package size]
| Order No. | 3-6823-01 | |
|---|---|---|
| Model No. | ADL12 | |
| JAN Code | 4582110977992 | |
| Standard price |
JPY: 68,000
USD: 426.25
Excange rate 1USD= 159.53JPY
Valid price in Japan |
|
| Quantity | 1piece | |
|
|
||
| Stock in Japan | - | |
Similar Products
1 / 1 ページ
Related Products
Product Catalog
| Catalog Name | Page |
|---|---|
| ASTOOL Catalog 2018>2019 [Indirect Materials for Manufacturing] | 75 |
| AS ONE Catalog 2019 [Instruments for Laboratory] | 580 |
| AS ONE Catalog 2017 [Instruments for Laboratory] | 457 |
| ASTOOL Best selection [Indirect Materials for Manufacturing] | 27 |
| ASTOOL Catalog 2016>2017 [Indirect Materials for Manufacturing] | 81 |
![[Discontinued]12 CH Data Logger, Main Unit, Temperature, Voltage and Humidity Measurement 167 x 91 x 35.8mm ADL12](https://aimg.as-1.co.jp/c/3/6823/01/03682301.jpg?v=03790be0f2ba82c1280907a7033cf49dabaaa7c1)
![[Discontinued]12 CH Data Logger, Main Unit, Temperature, Voltage and Humidity Measurement 167 x 91 x 35.8mm ADL12](https://aimg.as-1.co.jp/c/3/6823/01/03682301e.jpg?v=03790be0f2ba82c1280907a7033cf49dabaaa7c1)
![[Discontinued]12 CH Data Logger, Main Unit, Temperature, Voltage and Humidity Measurement 167 x 91 x 35.8mm ADL12](https://aimg.as-1.co.jp/c/3/6823/01/03682301bs.jpg?v=03790be0f2ba82c1280907a7033cf49dabaaa7c1)
![[Discontinued]12 CH Data Logger, Main Unit, Temperature, Voltage and Humidity Measurement 167 x 91 x 35.8mm ADL12](https://aimg.as-1.co.jp/c/3/6823/01/03682301c.jpg?v=03790be0f2ba82c1280907a7033cf49dabaaa7c1)
![[Discontinued]12 CH Data Logger, Main Unit, Temperature, Voltage and Humidity Measurement 167 x 91 x 35.8mm ADL12](https://aimg.as-1.co.jp/c/3/6823/01/03682301f.jpg?v=03790be0f2ba82c1280907a7033cf49dabaaa7c1)
![[Discontinued]12 CH Data Logger, Main Unit, Temperature, Voltage and Humidity Measurement 167 x 91 x 35.8mm ADL12](https://aimg.as-1.co.jp/c/3/6823/01/03682301d.jpg?v=03790be0f2ba82c1280907a7033cf49dabaaa7c1)
![[Discontinued]12 CH Data Logger, Main Unit, Temperature, Voltage and Humidity Measurement 167 x 91 x 35.8mm ADL12](https://aimg.as-1.co.jp/c/3/6823/01/03682301g.jpg?v=03790be0f2ba82c1280907a7033cf49dabaaa7c1)
![[Discontinued]12 CH Data Logger, Main Unit, Temperature, Voltage and Humidity Measurement 167 x 91 x 35.8mm ADL12](https://aimg.as-1.co.jp/c/3/6823/01/03682301a.jpg?v=03790be0f2ba82c1280907a7033cf49dabaaa7c1)
![[Discontinued]12 CH Data Logger ADL12N](https://aimg.as-1.co.jp/t/3/6823/31/03682331s_EC.jpg?v=03790be0f2ba82c1280907a7033cf49dabaaa7c1)